Page 3 1000001731 (Rev. J - 04/18)
EZSDWS*1F EZS8WS*1F, 2F, 3F LZSDWS*1F, 2F, 3F LZS8WS*1F, 2F, 3F
F
E
A
B
7/16" X 3/4" OBROUND
(11mm X 19mm) HOLES (6)
C
D
E
9/32"O HOLES
(7mm) (12)
FINISHED FLOOR
L
C
7"
178mm
7"
178mm
17 7/8"
454mm
6 3/8"
162mm
6 3/8"
162mm
2"
51mm
2"
51mm
5 3/4"
146mm
13 15/16"
354mm
17 7/16"
443mm
19"
483mm
28 13/16"
732mm
51 9/16"
1310mm
18 7/8"
479mm
12 1/2"
318mm
31 5/16"
796mm
RIM
HEIGHT
32 7/8"
835mm
ORIFICE
HEIGHT
21 7/8"
556mm
2"
51mm
3 7/8"
98mm
7"
178mm
7"
178mm
28 13/16"
732mm
2"
51mm
2 7/8"
73mm
15"
381mm
27"
686mm
ADA
REQUIREMENT
8 1/16"
205mm
19"
483mm
3 9/16"
90mm
5 7/8"
150mm
3"
77mm
2"
51mm
38 1/2"
979mm
ACTIVATION
SENSOR
HANGER BRACKET
Fig. 2
*ADA REQUIREMENT
*REQUISITO DE A.D.A.
*EXIGENCE ADA
REDUCE HEIGHT BY 3 INCHES FOR INSTALLATION OF CHILDREN’S ADA COOLER
LEGEND/LEYENDA/LÉGENDE
A = RECOMMENDED WATER SUPPLY LOCATION. SHUT OFF VALVE (NOT FURNISHED) TO ACCEPT 3/8 O.D. UNPLATED COPPER TUBE.
POSICIÓN DE ABASTECIMIENTO DE AGUA RECOMENDADA. VÁLVULA CERRADA (NO AMUEBLADO) PARA ACEPTAR 3/8" O.D. TUBO DE COBRE NO PLATEADO.
ENDROIT D’APPROVISIONNEMENT EN EAU RECOMMANDÉ. LA VALVE ARRÊTÉE (NON FOURNI) POUR ACCEPTER 3/8" PO. (9,5mm) TUBE COULEUR CUIVRE
NON PLAQUÉ.
B = RECOMMENDED LOCATION FOR WASTE OUTLET 1-1/4” O.D. DRAIN
UBICACIÓN RECOMENDADA PARA EL DRENAJE DE SALIDA DE AGUA, DE 1¼” DE DIÁMETRO.
EMPLACEMENT RECOMMANDÉ POUR LE DRAIN DE D.E. 1-1/4" DE SORTIE D’EAU.
C = 1-1/4 TRAP NOT FURNISHED**
PURGADOR DE 1¼ NO PROPORCIONADO**
SIPHON 1-1/4 NON FOURNI**
LEGEND/LEYENDA/LÉGENDE
D = ELECTRICAL SUPPLY (3) WIRE RECESSED BOX DUPLEX OUTLET**
SUMINISTRO ELÉCTRICO (3) CAJA ENCHUFE DE ALAMBRE SALIDA DÚPLEX
ALIMENTATION ÉLECTRIQUE (3) BOÎTIER ENCASTRÉ
E = INSURE PROPER VENTILATION BY MAINTAINING 6” (152 mm) (MIN.) CLEARANCE FROM CABINET LOUVERS TO WALL.
ASEGURE UNA VENTILACIÓN ADECUADA MANTENIENDO UN ESPACIO E 6” (152 mm) (MÍN.) DE HOLGURA ENTRE LA REJILLA
DE VENTILACIÓN DEL MUEBLE Y LA PARED.
ASSUREZ-VOUS UNE BONNE VENTILATION EN GARDANT 6” (152 mm) (MIN.) ENTRE LES ÉVENTS DE L’ENCEINTE ET LE MUR.
F = 7/16 BOLT HOLES FOR FASTENING UNIT TO WALL
AGUJEROS DE LAS TUERCAS DE 7/16 PARA SUJETAR LA UNIDAD A LA PARED
TROUS D’ÉCROUS 7/16 POUR FIXER L’APPAREIL AU MUR
**NEW INSTALLATIONS MUST USE GROUND FAULT CIRCUIT INTERRUPTER (GFCI)
**Las nuevas instalaciones deben utilizar el interruptor de circuito de tierra de la avería (GFCI)
**Les nouvelles installations doivent employer l’interrupteur de circuit moulu de défaut (GFCI)
*

Other manuals for Elkay LZS8WS 1F Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Elkay LZS8WS 1F Series and is the answer not in the manual?

Elkay LZS8WS 1F Series Specifications

General IconGeneral
BrandElkay
ModelLZS8WS 1F Series
CategoryWater Dispenser
LanguageEnglish

Related product manuals