PRODUCT INSTRUCTIONS
Mini Standard V7 3phase Controller
Dallimore Rd, Wythenshawe,
Manchester. M23 9NX
T: +44 (0)161 945 4561
F: +44 (0)161 945 4566
Stock Code Description Doc No: PI-110
01003 Dalmatic Mini Standard V7 Controller
Iss: 1
Controller
Specification
Supply voltage: 3ph - 400VAC ± 10% L1,L2,L3,PE (‘N’ not required)
50/60Hz,
Mains supply protection should be provided by
either 10A/phase MCB Type ’C’ or fuse equivalent
Maximum Load Max motor load by 3 x 400VAC: 4 kW
Temperature range -10…+50°C (operating)
Humidity: Up to 93% RH non-condensing.
Auxiliary Supply 24VDC ± 20% (non-regulated)
Max load: 250mA
(without additional plug-in options)
Safety edge input: Pneumatic air switch (N/C Contact)
Electric type - 8k2 termination ± 10%
Optical type (Fraba OSE or Dalmatic TSS/RSS)
Photo sensor input Photo-sensor, 24 VDC, Relay O/P N/C
Description
The Mini-Std controller has been designed as a controller which provides the
capabilities to operate an industrial door safely under electrical control by means of
a pushbutton station or key switch
Its intended use is to be connected to a suitable motor not exceeding the load for
the controller
The unit incorporates safety features to protect people or property from damage by
automatically reversing a closing door should they be activated
This together with the auto closing function and additional facilities for plug in Loop
Detectors and radio control make this unit very versatile
Connections are provided for Mains supply, Motor power, Travel Limits switches,
Push Buttons, Photocell and Safety Edge and 24VDC Auxiliary power (250mA max)
Question and Answer IconNeed help?

Do you have a question about the Ellard Mini Standard V7 and is the answer not in the manual?

Ellard Mini Standard V7 Specifications

General IconGeneral
BrandEllard
ModelMini Standard V7
CategoryController
LanguageEnglish

Summary

Types of Operation

Dead man Open / Close

Motor stops when control button is released; requires continuous press.

Impulse Open / Dead man Close

One press opens, press and hold closes the door.

Impulse Open / Close

One press opens, another press closes; requires monitored safety edge.

Service Counter

Setting the Service Interval Counter

Guide to setting the service interval counter using S1 Dipswitches.

Resetting the Service Interval Counter

Procedure to reset the service interval counter using pushbuttons and LED confirmation.

Disabling the Service Interval Counter

How to disable the service interval counter using S1 Dipswitches and LED confirmation.

LED Status Indicators

Explanation of LED descriptions, colours, statuses, and their meanings.