13
220V 240V Line voltage
LO parameter value
Line Voltage
HI parameter value
Line Voltage
130
173V
190
230V
135
178V
195
235V
140
182V
200
240V
145
187V
205
245V
150
192V
210
250V
155
197V
215
255V
160
203V
220
260V
225
265V
100V Line voltage (Japan)
Line voltage
LO parameter value
HI parameter value
79V
120
175
81V
125
180
84V
130
185
87V
135
190
90V
140
195
SWITCHING THE LIGHTS ON/OFF
The EMS automatically controls the lights of the cooler and will switch them off during stand-by and
back on during operational periods.
MANAGING THE INTERNAL FAN(S)
The EMS switches the internal evaporator fan(s), which gives the following benefits.
During periods when the compressor is off the fan(s) will cycle and not only will this save
energy but will increase the life expectancy of the fan(s) themselves.
When the cooler door is opened, the fan(s) are switched off (even when the compressor is
running). This means that the cold air in the cooler will not be pushed out and no ambient
(warm) air will be drawn in.
During an uninterrupted pull down the fan(s) will be run continuously even if the door is open.
THE DOOR OPEN ALARM
If the door of an appliance is accidentally left open the following would result:
A rise in temperature of the load inside the appliance
A substantial waste of energy to restore the required situation
Additional and unnecessary running hours for the refrigeration system