SUPPLEMENT
E43 AND E46 FIRMWARE DIFFERENCES
Standard EMS firmware version has been updated from E43 to E46, for which the following changes
have been made:
1. The display will show the cabinet temperature during operational mode rather than showing
USE.
2. The set point, differential, standby set point and standby differential can be set in 0.1 degree
increments.
3. A new parameter PER (perishable mode) has been introduced which means the operational
set point and differential are used during standby mode. This parameter is now listed in the
statistics scroll.
4. The standby set point is now added to the operational set point to give the cut out
temperature during standby.
5. The HT alarm must now be reset manually by pressing the DOWN button.
6. The display stability (parameter D1) has been altered so that it changes only in 0.1 degree
steps.