Application and Operation
Additional label information depending on the applicable approval
(see following label examples)
Please see below for an explanation of each label type using an Ultrasonic
Flow Meter Series 6 Q.Sonic
Plus
model as an example.
ATEX Certification
The explosion proof housing has the following ATEX certification
information:
Classification: Ex II 2 G Ex d ia [ia] IIB+H2 T6 Gb IP66
-50 °C ≤ Tamb ≤ +60 °C
ATEX markings: II 2 G 0044
o 0044 is the Notified Body number of DEKRA
Certification B.V.
ATEX certificate reference: DEKRA 11ATEX0170 X
Warning: Read instruction manual before operating device
Figure 3-2: Example of an ATEX Label
IECEx Certification
The explosion proof housing has following IECEx certification information:
Classification: Ex d ia [ia] IIB+H2 T6 Gb IP66
-40 °C ≤ Tamb ≤ +60 °C
IECEx certificate reference: IECEx DEK11.0062 X
Warning: Read instruction manual before operating device