6. Troubleshooting guide
6.1 Why wont it do that?
Having described the many things you can do with a 1000 Series Squirrel,
here are just a few operations that are not possible: -
· clear the memory while logging is in progress
· start logging when the memory is full
· start logging if no channels have been selected
· perform multiple runs if memory is in continuous mode
· reset pulse count while logging is in progress
· change date and time while logging
· change start date and time while logging
· change log and sample intervals while logging
It is not possible to change the following either when there are readings
stored in memory or when logging is in progress:
· Log mode
· External trigger mode
· Memory mode
· Channel set up and ranges
· Engineering unit ranges
· Memory size
· Language type
· Sensor switch on time
· Date format
· Filter frequency