Operating Instructions
KNH35 High Voltage Generator
BA-en-3031-2004
F00038y

Questions and Answers

  • B
    Brian RileyAug 21, 2025
    Why is my ELTEX KNH65 not switching on?
    • H
      Holly WilsonAug 21, 2025
      Your ELTEX Portable Generator might not be switching on due to a defective fuse or because the supply voltage is not connected. You should replace the fuse, referring to the name plate for the correct type. Also, ensure that the supply voltage is properly connected and activated.
  • A
    Antonio HigginsSep 2, 2025
    What does error text: 05 no voltage mean for my ELTEX Portable Generator?
    • A
      Abigail HernandezSep 3, 2025
      The error text '05 no voltage' indicates an error in high voltage generation. Acknowledge the error, and if it recurs, send the unit for repairs.
  • L
    lindseyshawSep 1, 2025
    What should I do if my ELTEX Portable Generator shows error text: 12 EEPROM error?
    • T
      Timothy McdonaldSep 1, 2025
      If your ELTEX Portable Generator displays error text '12 EEPROM error', switch the appliance off and then back on. If the error continues, it indicates a memory problem, and the unit should be sent for repairs.
  • U
    uparsonsAug 31, 2025
    What does error text: 01 limiter mean for my ELTEX KNH65 Portable Generator?
    • Y
      Yesenia HernandezAug 31, 2025
      The error text '01 limiter' indicates that the limiter is set to , and the selected value has been exceeded. Investigate the cause of why the limit value was exceeded. If necessary, increase the limit value.
  • S
    Sean LawrenceAug 29, 2025
    What does error text: 03 spark counter 2 mean on my ELTEX KNH65 Portable Generator?
    • B
      brittanyyatesAug 29, 2025
      The error text '03 spark counter 2' indicates that the processor measuring range was exceeded. To resolve this, reduce the output voltage, clean the bars (see Maintenance), and check the high voltage cables.
  • M
    Meghan SanchezAug 27, 2025
    What does error text: 16 mains voltage mean on my ELTEX Portable Generator?
    • B
      Barbara CarterAug 27, 2025
      The error text '16 mains voltage' on your ELTEX Portable Generator indicates that the generator, operating with 115 V mains voltage, has detected a non-permissible mains voltage. Acknowledge the error by switching the generator off and then back on. If the error reappears, inspect the supply network for voltage peaks and contact Eltex if needed.
  • A
    Adam SchmidtAug 26, 2025
    What to do if my ELTEX KNH65 Portable Generator displays error text: 02 spark counter 1?
    • W
      william46Aug 26, 2025
      If your ELTEX Portable Generator displays the error text '02 spark counter 1', it means there were 5 high-power discharges within a short period. To fix this, reduce the output voltage and clean the bars as described in the Maintenance section.
  • C
    Christine HullAug 25, 2025
    What does error text 30 temperature rise mean for my ELTEX KNH65 and how to fix it?
    • T
      Timothy BrownAug 25, 2025
      Error text 30 'temperature rise' indicates that the internal temperature of your ELTEX Portable Generator is too high. Here's what you can do: * Check the maximum permissible temperature and reduce the generator load if necessary. * Verify the installation position, as heat loss is best when the generator is mounted in a hanging position. * Ensure adequate air circulation if the generator is inside a cabinet.
  • J
    Jennifer WiseAug 23, 2025
    What to do if my ELTEX KNH65 Portable Generator displays error text: 04 short-circuit?
    • C
      Chad WileyAug 23, 2025
      If your ELTEX Portable Generator displays the error text '04 short-circuit', it indicates a short-circuit has been detected. To resolve this, disconnect the connected consumers one after the other to identify and isolate the short-circuit.

Summary

Safety

Identification of risks and hazards

Symbols identifying potential risks and hazards during operation.

Work and operational safety

Essential safety rules and precautions for safe operation and maintenance.

Installation

Ground connection

Requirements for establishing a permanent and safe ground connection.

Operation

Start-up

Procedure for powering on the generator and initial operation.

Overview of functions with options and factory settings

Details on specific setting options and default factory configurations for the generator.

Selecting the operating parameters (Password protection)

Accessing and modifying operating parameters requires password entry.

Maintenance

Troubleshooting

Error messages

List of common defects, their causes, and recommended remedies.