CMe3100 DLMS Plugin User's Manual
CMe3100 DLMS Plugin User's Manual
page | 24 (48)
2022-02-23
Version 1.8
6.4.2 Set DLMS server settings report receiver
Configure desired DLMS servers which should receive the Push Report in the DLMS server
settings report receiver section, see Figure 13.
Use the default server settings by check the Send report to default DLMS server checkbox. If the
default server settings shouldn’t be used, uncheck the checkbox and enter the desired DLMS
server in Default address and Port. The Backup address and Port can be used as a fallback
server if the report fails when sending report to the default address.
Figure 13 DLMS server settings - report receivers
A test report can also be triggered by clicking the Save and Send test report button.
6.5 Enable Push Report of Standard event log/Fraud detection log
Standard event log and fraud detection log is configured in the same way as for load
profile/billing profile, see section 6.4.
Select 9001 (Standard event log) or 9002 (Fraud detection log) in the Report template drop-down
to enable desired log report.
Each report will push all events for both the gateway and the meters.