CMe3100 DLMS Plugin User's Manual
CMe3100 DLMS Plugin User's Manual
Attributes:
1: Logical name
2: Push Object List
3: N/A
4: N/A
5: N/A
6: N/A
7: N/A
7.5.1.21 Security setup
The security setup object enables read/write of keys and policy used in security suite 0.
For the key exchange, the HES calls methods of the security setup (version 0), OBIS code
0.0.43.0.0.255. The only keys that are to be exchanged are those of the gateway. There are no
separate keys for the meters. The key exchange is to be executed as specified by [1] 9.2.5.4 and
[4] 9.4.6.1.
When writing to the security setup object, the new security configuration will NOT be used until a
disconnect and a new connection is made.
7.5.2 Meter logical device COSEM objects
Following COSEM objects are available in each meter logical device:
Gateway Logical Device Name
Standard Event Log - Event Id
Standard Event Log - Event
Message
Fraud Event Log - Event Id
Fraud Event Log - Event
Message