Elvaco CMe3100 DLMS Plugin - Event Triggered Push of Data

Default Icon
48 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
CMe3100 DLMS Plugin User's Manual
CMe3100 DLMS Plugin User's Manual
page | 42 (48)
2022-02-23
Version 1.8
<octet-string>timestamp of the event</octet-string>
<octet-string>OBIS code of the event object</octet-string>
<unsigned>event code</unsigned>
Optionally, it may also contain another item:
<visible-string>custom event message</visible-string>
OBIS codes used:
Timestamp: 0.0.1.0.0.255
Event object: 0.0.96.11.0.255 (Standard), 0.0.96.11.1.255 (Fraud)
Custom event message: 0.128.96.11.0.255 (Standard), 0.128.96.11.1.255 (Fraud)
7.6.2 Event triggered push of data
7.6.2.1 Push On-Installation Event
This event is triggered when the meter list of a gateway is changed. The event triggers a push
with the event code On-Installation, which can be used by the HES to trigger a poll operation to
update the meter list (read meter list from the gateway).
The gateway will only trigger a single push, even if more than one meter is added/removed
during an operation. The hysteresis for grouping the event is three (3) minutes.
The payload of the Data Notification APDU has the following structure:
<octet-string>COSEM logical device name of the gateway</octet-string>
<octet-string>COSEM logical name of the push setup on installation
object</octet-string>
<double-long-unsigned>ip adress of the gateway</double-long-unsigned>
<octet-string> System title of the gateway as defined in [4] 6.1.1</octet-
string>
The OBIS code for the push setup on installation object is fixed to 0-7:25.9.0*255 (see [4],
section 7.2.1).