TRAVEL PATH LEARNING
There are two travel path learning modes:
1. Easy Learning
2. Learning
To activate easy learning, keep the Prog. A button pressed. After 2 seconds the red LED starts to flash slowly, when the button is released the LED will
continue to flash slowly. Then simply press APCH once and the learning procedure will take place automatically without any user intervention. The ope-
ning and closing slow-down points are set by default to 70% and 30% of the total travel.
NOTE: during the Easy Learning procedure (LRNE), slow-down does not occur during the first opening manoeuvre.
To activate easy learning, keep the Prog. A button pressed. After 4 seconds the red LED starts to flash rapidly, when the button is released the LED will
continue to flash rapidly. Press APCH to start the reclosure manoeuvre.
The learning procedure will continue according to the steps indicated in the following table.
NOTE: you can interrupt the procedure at any time by activating the STOP input. The red LED will flash rapidly for several seconds and will then switch off. In this case
no learned parameter is saved.
NOTE: if at the start of the procedure the OPEN/CLOSE input is not activated within 30 seconds, learning mode will exit and the red LED will flash rapidly.
STEP MEANING
START LEARNING Activate OPEN/CLOSE input (also on the radio control, if configured). Starts closure
manoeuvre.
INITIAL CLOSURE Initial closure, wait for the automation to reach the fully closed position
OPENING Opening manoeuvre.
Activate OPEN/CLOSE to set the opening slow-down starting point.
OPENING SLOW-DOWN Opening slow-down, wait for the automation to reach the fully open position or ac-
tivate OPEN/CLOSE to set the point at which the automation is considered open.
pause time learning.
PAUSE TIME LEARNING Wait for a time equal to the pause time that you want to set for the “Automatic re-
closure” function. Activate OPEN/CLOSE to store the time.
CLOSURE Manoeuvre. Activate OPEN/CLOSE to set the closing slow-down starting point.
CLOSING SLOW-DOWN Closing slow-down, wait for the automation to reach the fully closed position.
PEDESTRIAN OPENING
LEARNING
Slow opening manoeuvre. Activate OPEN/CLOSE to set the point at which the au-
tomation is considered "pedestrian open" (partial opening) (SLIDING mode only)
FINAL CLOSURE Closing manoeuvre, wait for the automation to reach the fully closed position (SLI-
DING mode only)
END
Procedure successfully completed. The parameters are saved in the memory.