ENG 40 TROUBLESHOOTING
7. TROUBLESHOOTING
PROBLEM SITUATION LIKELY CAUSE SOLUTIONS
1. Pilot lamp off
2. Starter motor
not working
3. Engine does
not start
Key is in «ON»
position, engi-
ne stopped
Key in
«START»
position and
pilot lamp on
Key in
«START»
position and
pilot lamp fla-
shing
Key in
«START»
position
Electronic card in safety alert, due
to:
badly connected battery
completely flat battery or eroded
battery plates
battery terminals crossed
fuse blown
badly earthed
electronic card wet
earthed micro-switches
insufficiently charged battery
badly earthed
you are not ready for starting
no fuel supply
faulty ignition
Put the key in the «OFF»
position and look for the
cause of the problem:
check connections
recharge battery
connect properly
replace fuse (6.3 A -
delayed)
check connections
dry by air
check connections
recharge battery (if the pro-
blem continues, consult a
Licensed Service Centre)
check connections
check that the blade is
disengaged (if the problem
continues, check relevant
micro-switch)
put the gear
(
mechani-
cal) or the lever
(
hydrostatic) in neutral (N)
check fuel level
open fuel stop-cock (where
fitted)
check the wiring of the fuel
open command (where fit-
ted)
check fuel filter
check that spark plugs caps
are firmly fitted
check that the electrodes
are clean and have the cor-
rect gap