EasyManuals Logo

EMC Connectrix B Series Reference Manual

EMC Connectrix B Series
76 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #17 background imageLoading...
Page #17 background image
1
Elements and Components
1-5
Introducing Fabric Watch
Port Link failure count (link
loss)
Monitors the link failure rate of
each port. Tracks the number of
link failures per configured time
interval.
Loss of
synchronization count
Monitors the number of
synchronization loss errors per
configured time interval.
Loss of signal count Monitors the number of signal
loss errors per configured time
interval.
Primitive sequence
protocol error
Monitors the number of protocol
errors per configured time
interval.
Invalid transmission
word
Monitors the number of invalid
words transmitted (from a device
to a port) per configured time
interval.
Invalid CRC count Monitors the number of CRC
errors per configured time
interval.
Receive performance Monitors receive rate in KB/s.
Transmit performance Monitors transmit rate in KB/s.
State changes Monitors state changes.
SFP Temperature Monitors SFP temperature in
degrees Celsius.
Receiver power Monitors SFP receiver power in
uwatts.
Transmitter power Monitors SFP transmitter power
in uwatts.
Current Monitors SFP current in mamps.
Table 1-1 Fabric Watch Areas (
continued
)
Class Area Area Description

Other manuals for EMC Connectrix B Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the EMC Connectrix B Series and is the answer not in the manual?

EMC Connectrix B Series Specifications

General IconGeneral
BrandEMC
ModelConnectrix B Series
CategorySwitch
LanguageEnglish

Related product manuals