INSTALLER/CONFIGURATION MENU
Menu
Reference
Number
Press
Key
Displayed
(Factory
Default)
Press
or
to select from
listed options
Comments
6
and
L
(On)
OFF SelectDisplayLightOnorOFF
7
and
Temp
(0HI)
4 LO to
4HI
Selecttemperaturedisplayadjustmenthigheror
lower
8
and
o
F
o
C Select
o
F/
o
CDisplay(temperatureunitsinFahren-
heitorCelsius)
9
and
Change Filter
(OFF)
On SelectlterreplacementindicatorOFForOn
and
Change Filter
(200h)
25to1975 If Change Filter selected On, selects time interval for
ChangeFilterIndicator.(in25hourincrements)
10
and
Returns to normal operation
1) System Configuration-SelectsSS(SingleStage)orHP
(HeatPump)operatingmode.DefaultcongurationisSS.
ForHeatPumpoperationchooseHP.
2) Select CS (Cool Savings™) - With Cool Savings™
enabled, the thermostat will make small adjustments to
the Setpoint temperature during periods of high demand
to reduce cooling system running time and save energy.
Whenthecoolingsystemhasbeenrunningformorethan
20minutes,humidityinthehomewillbelowerandahigher
setpointtemperaturewillfeelcomfortable.After20minutes
of run time, the thermostat will start increasing the setpoint
temperature in steps of less than one degree as the system
continuestorun.Theseadjustmentswilleventuallycause
the system to satisfy the thermostat and turn the system off
toreducetheenergyconsumption.WhentheCoolSavings
featureisactiveandmakingadjustments,thedisplaywill
show“Save”.Theamountoftheadjustmentstothesetpoint
temperatureisdependentontheCoolSavingsvaluethat
isset,1beingtheleastadjustmentand6beingthemost
adjustment.With this feature set to OFF, no change will
occur when the cooling system is continuously running
duringtheperiodsofhighdemand.Periodsofhighdemand
will normally occur during the late afternoon and early
evening on the hottest days of the summer.
3 & 4) Select Cycle Rate Selection - The factory default
settingforSingleStage Heat is Medium Cycle (ME). For
SingleStageCoolthedefaultsettingisfast(FA).Tochange
cycle rate, press the
and buttons.
The cycle rate differentials for different settings are:
MODE Fast Medium Slow
(FA) (ME) (SL)
SSHeat 0.6°F 0.8°F 1.2°F
SSCool 1.2°F - 1.7°F
5) Select Compressor Lockout CL OFF or ON-Selecting
CLOnwillcausethethermostattowait5minutesbetween
cooling cycles. This is intended to help protect the
compressorfromshortcycling.Somenewercompressors
already have a time delay built in and do not require this
feature. Your compressor manufacturer can tell you if the
lockoutfeatureisalreadypresentintheirsystem.Whenthe
thermostatcompressortimedelayoccurs,itwillashthe
setpoint for up to five minutes.
6) Select Backlight Display-Thedisplaybacklightimproves
display contrast in low lighting conditions. When the “C”
terminal is connected, selecting backlight CdL On will keep
thelightoncontinuously.SelectbacklightOFFwillturnthe
lightonmomentarilywhenanykeyispressed.Whenthe
“C”terminal is not connected,regardlessofthebacklight
selection, the light will be on momentarily when any key is
pressed.
7) Select Temperature Display Adjustment 4 LO to 4 HI-
Allowsyoutoadjusttheroomtemperaturedisplayupto4°
higher or lower. Your thermostat was accurately calibrated
at the factory but you have the option to change the display
temperature to match your previous thermostat. The
currentoradjustedroomtemperaturewillbedisplayedon
the display.
8) Select F° or C° Readout-Changesthedisplayreadoutto
Celsius or Fahrenheit as required.
9)Select Filter Replacement Reminder and Set Run Time
Selectthe“Change Filter” reminder On or OFF. If selected
On, press
and toselectthetimeperiodfrom25to
1975hoursin25hourincrements.Inatypicalapplication,
200hours(default)of runtime is approximately30days.
After the selected time of blower operation, the thermostat
will display “Change Filter” as a reminder to change or
clean your air lter. When “Change Filter” is displayed,
press the and button to clear the display and
restart the time to the next filter change. A selection of OFF
will cancel this feature.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Emerson 1F86-0244 and is the answer not in the manual?

Emerson 1F86-0244 Specifications

General IconGeneral
Display TypeDigital
Stages1 Heat/1 Cool
BacklightYes
MountingWall
Compatibilitygas, oil, electric systems
Voltage24 VAC
Temperature Range45°F to 90°F
ProgrammableNon-programmable
Power SourceBattery or Hardwired

Related product manuals