153
Diagnostics and Troubleshooting
Analog Output Source options are:
Velocity Command
Velocity Feedback
Torque Command (equates to Torque Command Actual parameter)
Torque Feedback
Following Error
Default Analog Output Source:
Channel 1 = Velocity Feedback
Channel 2 = Torque Command
Figure 111: Diagnostic Analog Output Test Points
The DGNE cable was designed to be used with either an oscilloscope or a meter. The wires
are different lengths to avoid shorting to each other. However, if signals do get shorted to
GND, the drive will not be damaged because the circuitry is protected.
Channel Output Source Offset Scale
1 Velocity Feedback 0 600 RPM/volt
2 Torque Command 0
30 percent/volt for selected
motor
Channel #2
Channel #1
Analog GND
E Series Drive
Epsilon Drive
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Table of Contents

Other manuals for Emerson Control Techniques EN-214

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Emerson Control Techniques EN-214 and is the answer not in the manual?

Emerson Control Techniques EN-214 Specifications

General IconGeneral
BrandEmerson
ModelControl Techniques EN-214
CategoryDC Drives
LanguageEnglish

Related product manuals