Model | MP45A4R |
---|---|
Type | DC Drive |
Output Current | 45 A |
Enclosure Rating | NEMA 1 |
Protection Features | Short Circuit |
Operating Temperature | 0°C to 50°C |
Cooling Method | Convection |
Covers warnings, cautions, electrical safety, system design, and parameter adjustment safety.
Covers safety aspects related to electrical installation, including shock risks and isolation.
Details power ratings, current ratings, and specifications for 480V, 575V, and 690V configurations.
Covers safety, planning, access, environmental protection, cooling, and EMC considerations.
Details mounting methods and dimensional drawings for various Mentor MP drive sizes.
Information on enclosure layout, sizing, and calculating airflow.
Illustrates terminal locations for power and ground connections across different drive sizes.
Covers critical safety aspects including electric shock risks, isolation, and STOP function.
Provides wiring diagrams for power connections (480V and 575V/600V/690V drives).
Details grounding requirements and connection locations for different drive sizes.
Covers AC supply types, fault current, and MOV ground disconnect procedures.
Details AC supply specifications, line reactors, and current ratings.
Provides guidance on selecting appropriate cables and fuses based on drive ratings.
Lists recommended Ferraz Shawmut fuses for semiconductor, branch circuit, and DC protection.
Details internal field fuses and external suppressor resistor specifications.
Summarizes EMC performance requirements and filter recommendations.
Covers serial port details, isolation, and multi-drop network configuration.
Provides guidance on shield connections for EMC compliance and fan connection for size 2 drives.
Details control connection functions, cable sizes, and general terminal specifications.
Explains Menu 0's sub-block mode, coding attributes, keypad navigation, and sub-block structure.
Covers relay output functions and encoder feedback connection methods.
Describes the SM-Keypad and MP-Keypad displays, showing drive status and parameters.
Explains keypad buttons, display modes, and examples of mode transitions.
Details Menu 0 sub-block structure, coding, keypad navigation, and parameter access.
Explains Menu 0 in linear mode and the overall drive menu structure.
Covers parameter access levels, user security settings, and default differences.
Guides for initial setup and commissioning from European and USA default settings.
Details how to save and read parameter sets and data blocks using the SMARTCARD.
Covers procedures for writing, reading, erasing, and comparing data with the SMARTCARD.
Specifies parameters related to enabling and monitoring the onboard PLC program.
Provides guidance on selecting appropriate cables and fuses based on drive ratings.
Details torque settings and EMC compliance standards for the drive.
Explains trip indications, categories, and how to cross-reference them.
Provides diagnostic information for various trip codes, including SMARTCARD and PLC errors.
Covers UL listing requirements, installation, safety, and supply specifications.