8
Epsilon Eb and EN Drives Reference Manual
Pulse frequency > 250 kHz
Pulse command cable length > 25 feet
Noisy electrical environments
Differential input circuit specifications:
Input frequency maximum 2 Mhz
Input device: AM26C32
Input impedance 12 Kohms each input
Maximum voltage applied to input pins (A, A/) or (B, B/ )
Single Ended (referenced to 0V drive logic) +/-10V
Differential (referenced to mating differential input) +/-10V
Maximum common mode voltage +/-7 V
Minimum differential voltage required 200 mV
Input voltage hysteresis 60 mV
Single ended input circuit specifications:
Single ended input specifications:
1 MHz maximum input frequency
Internal 330 ohm pull-up to 5 Volt (non-isolated)
1.5 Volt low level
3.5 Volt high level
Output driver requirements:
15 mA sinking (open collector)
5 Volt capacity
ECI-44 Terminal
Command
Connector Pin #
Pulse-Direction
Signal
Pulse-Pulse
Signal
Pulse Quadrature
Signal
Sync Enc In “A” 27 Pulse Pulse + A
Sync Enc In “A/” 41 Pulse/ Pulse +/ A/
Sync Enc In “B” 26 Direction Pulse - B
Sync Enc In “B/” 40 Direction/ Pulse -/ B/
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Table of Contents

Other manuals for Emerson Control Techniques EN-214

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Emerson Control Techniques EN-214 and is the answer not in the manual?

Emerson Control Techniques EN-214 Specifications

General IconGeneral
BrandEmerson
ModelControl Techniques EN-214
CategoryDC Drives
LanguageEnglish

Related product manuals