7
ESDS Manual
S14006
4/15/92
(7) The components can now be handled following the general rules as described
in the instruction manual for the component.
(8) Place the component in a static-shielding bag before the ground cord is
disconnected. This assures protection from electrostatic charge in case the work
surface is located beyond the reach of the extended ground cord.
NOTE: ALL RESISTORS 1M +/-10% 1/2W
FLOOR OF BUILDING
EARTH GROUND
A
B
C
D
E
F
G
R
R
R
R
A - Chair with ground (optional)
B - ESD protective floor mat (optional)
C - Wrist strap
D - ESD protective trays, etc.
E - Ionizer
F - Other electrical equipment
G - Workbench with ESD protective table top
LEGEND