User Guide
MHM-97927-PBF, Rev DRAFT
July 2020
AMS Wireless Vibration Monitor
User Guide

Other manuals for Emerson AMS

Questions and Answers

  • M
    Mr. John StevensAug 16, 2025
    What to do if Emerson Monitor shows device temperature warning?
    • L
      lisa02Aug 16, 2025
      If you see a device temperature warning on your Emerson Monitor, take appropriate measures to reduce the environmental temperature.
  • S
    Savannah JacksonAug 19, 2025
    What to do if Emerson Monitor shows supply voltage warning?
    • E
      Erik BlackAug 19, 2025
      If the Emerson Monitor displays a supply voltage warning, check the power supply.
  • T
    taylordanielAug 22, 2025
    What to do if the health value on my Emerson Monitor is between 60% and 90%?
    • P
      perezjoanAug 22, 2025
      If the health value on your Emerson Monitor is between 60% and 90%, open the AMS Asset Monitor Web Interface to check the configuration for any inconsistencies.
  • J
    Jacob ScottAug 25, 2025
    What to do if maintenance mode is active on Emerson Monitor?
    • H
      Heidi RussellAug 26, 2025
      If the maintenance mode is active on your Emerson Monitor, open the AMS Asset Monitor Web Interface to check whether an installed CHARM is disabled.
  • L
    Lisa GomezAug 28, 2025
    What to do if CHARM channel fault or hardware error in Emerson AMS?
    • J
      Jessica DillonAug 28, 2025
      If you're encountering a CHARM channel fault or hardware error with your Emerson Measuring Instruments, first, check the wiring and the field device associated with it. If both the wiring and device appear to be working correctly, the next step is to replace the CHARM.
  • J
    Jennifer BuckleyAug 30, 2025
    What to do if no supply voltage in Emerson Measuring Instruments?
    • A
      Angela CobbAug 31, 2025
      If your Emerson Measuring Instruments are not receiving any supply voltage, the first step is to check the power supply to ensure it is functioning correctly.
  • J
    jessicawhiteSep 3, 2025
    What to do if health value is between 60% and 90% in Emerson AMS Measuring Instruments?
    • H
      Haley ManningSep 3, 2025
      If the health value of your Emerson Measuring Instruments is between 60% and 90%, indicating an 'Advice state', open Asset Studio to get recommendations on how to solve the issue.
  • L
    Laura HerreraSep 6, 2025
    What to do if configuration required in Emerson AMS Measuring Instruments?
    • K
      Kelly WintersSep 6, 2025
      If your Emerson Measuring Instruments indicate that configuration is required, open Asset Studio to check the configuration for any inconsistencies.
  • R
    Robert EllisSep 9, 2025
    What to do if maintenance mode is active in Emerson AMS Measuring Instruments?
    • C
      Cassidy BellSep 9, 2025
      If your Emerson Measuring Instruments are showing that maintenance mode is active, open Asset Studio to check whether an installed CHARM is disabled.
  • W
    William PenaSep 12, 2025
    How to fix AMS Asset Monitor that does not respond (Emerson Measuring Instruments)?
    • M
      mcintoshmichelleSep 12, 2025
      If the AMS Asset Monitor from Emerson Measuring Instruments is not responding, reset it.

Summary

Introduction and Safety

Safety Messages

Safety precautions and warnings for device installation and operation.

AMS Wireless Vibration Monitor Overview

Monitor Features and Components

Details the monitor's sensors, features, and battery.

Device Variable Measurements

Lists supported measurements and their configuration as process variables.

Device Configuration

Configuration Setup Options

Describes three methods for configuring the AMS Wireless Vibration Monitor.

Wireless Network Setup

Explains setting wireless credentials like Network ID and Join Key.

Guided Setup Process

Explains the step-by-step Guided Setup process for device configuration.

Installation Procedures

Device Handling Precautions

Provides essential precautions for handling the device before and during installation.

Mounting Methods

Details stud mount, epoxy mount, and motor fin mount installation procedures.

Battery Replacement Guide

Provides detailed steps for safely replacing the device's battery.

Operation and Verification

Verifying Operation with AMS Trex Communicator

Explains how to check device status and configure using the AMS Trex communicator.

Wireless Gateway Verification Steps

Details how to verify device connectivity and communication via the Wireless Gateway.

Measurement Analysis

Understanding Overall Velocity

Explains Overall Velocity measurement and its use in fault detection.

PeakVue Advisory Level Guidelines

Shows guidelines and examples for setting PeakVue advisory alert levels.

Temperature Monitoring Methods

Discusses factors and methods for setting temperature alert thresholds.

Specifications and Certifications

Functional Specifications

Lists functional specifications including input, output, humidity, and measurement parameters.

Hazardous Location Certifications

Lists certifications for operation in hazardous locations (CSA, IECEx, ATEX).

Conditions for Safe Use in Hazardous Locations

Outlines specific conditions for safe operation in hazardous environments.

Emerson AMS Specifications

General IconGeneral
Output4-20 mA, Digital
Measurement TypeVibration, Temperature
Communication ProtocolModbus, WirelessHART
Operating Temperature Range-40°C to +85°C
Enclosure RatingIP66
Power SupplyBattery, External Power