22
© 2015 Emerson Climate Technologies, Inc.
AE4-1365 R4
Outdoor Ambient 85°F (29°C) 95°F (35°C) 105°F (40°C)
System On-Time (Minutes) 7 14 54
System Off-Time (Minutes) 13 8 6
Number of On/Off Cycles 5 5 4
Table 1
Field Application Test
Recommended Conguration
Component Description
TubingConguration Shock loop
Service Valve "Angled valve" fastened to unit
Suctionmufer Not required
Alternate Conguration
Component Description
TubingConguration Shock loop
Service Valve "Straight through" valve not fastened to unit
Mass/Suctionmufer May be required (Acts as dampening mass)
Table 2
Design Congurations
Table 3
Compressor Refrigerant Charge Limits
Model Frame Size*
Charge Limit 120% x Limit** Tandem Charge Limit
Pounds kg Pounds kg Pounds kg
ZP50 - 57K3
ZP70 - 83KW
ZP61 - 91KC
70
10.0 4.5 12.0 5.4 12.0 5.4
ZP104-122KC
ZP143KC
11.0 5.0 13.0 6.0 13.0 6.0
*Approximate Shell Diameter (e.g. 70 - 7.3 Inches)
**Charge Allowance For System