Quick Installation Guide
QIG 8000-81-003 Ed 01 February 2020
36
5. Use a fork wrench to hold the actuator spindle while tightening the screw. Tighten to Nm (Newton meter)
according to the table on next page.
Caution! Do not use any tools on the smooth/round surface of the actuator spindle.
Only use tools on the wrench-grip surfaces.
6. DPI models only! Insert the yoke into the DPI hole. Use a pair of long tweezers to position the yoke cor-
rectly in the small hole in the bottom of the DPI hole.
7. DPI models only! Insert the DPI socket into the hole and make 4-5 turns by hand for loose tightening.
8. Mount the bleed valve and tighten using a fork wrench or spanner. Tighten to 15-20 Nm (N
ewton meter).