Assembling the Actuator
Caution! To avoid damage of internal parts, it is very important that assembling is done in cor-
rect order and as described below.
Assembling the Actuator
1. Insert the long screw through the
bleed valve’s hole by use of the hex
key.
2. Insert the indicator bushing (wide end first) into the actuator’s cylinder hole …
3. … and at the same time lead the bolt through the indicator bushing until the bolt is visible at the narrow
end of the indicator bushing.
Caution! Models without DPI :
If assembling a model without DPI you must ensure (by visual check) that the yoke is positioned
correctly (not visible when looking into the actuator from the bottom) before mounting the indi-
cator bushing and make sure the actuator is placed on the side as shown on page 31, step 1.
4. Add Loctite 542 to the thread of the actuator spindle.
Insert the actuator spindle and mount it to the indicator bushing. Tighten slightly by hand.