11. ALARM SIGNALS
Alarm output ON; Compressor output according to
parameters “COn” and “COF”
Alarm output ON; Other outputs unchanged
Alarm output ON; Other outputs unchanged
Maximum temperature alarm
Alarm output ON; Other outputs unchanged
Minimum temperature alarm
Alarm output ON; Other outputs unchanged
Alarm output ON; Other outputs unchanged
Alarm output ON; Other outputs unchanged
Alarm output ON; Other outputs unchanged
Alarm output ON; Other outputs unchanged
Alarm output ON; Other outputs OFF
Alarm output ON; Other outputs OFF
The alarm message is displayed until the alarm condition is recovery.
All the alarm messages are showed alternating with the room temperature except for the “P1” which is flashing.
To reset the “EE” alarm and restart the normal functioning press any key, the “rSt” message is displayed for
about 3s.
11.1 SILENCING BUZZER
Once the alarm signal is detected the buzzer can be silenced by pressing any key.
11.2 “EE” ALARM
The Dixell instruments are provided with an internal check for the data integrity. Alarm “EE” flashes when a
failure in the memory data occurs. In such cases the alarm output is enabled.
11.3 ALARM RECOVERY
Probe alarms : “P1” (probe1 faulty), “P2” and “P3”; they automatically stop 10s after the probe restarts normal
operation. Check connections before replacing the probe.
Temperature alarms “HA” and “LA” automatically stop as soon as the thermostat temperature returns to normal
values or when the defrost starts.
Door switch alarm “dA” stop as soon as the door is closed.
External alarms “EAL”, “BAL” stop as soon as the external digital input is disabled “PAL” alarm is recovered by
switching OFF the instrument.
12. TECHNICAL DATA
Housing: self extinguishing ABS.
Case: facia 38x185 mm; depth 76mm
Mounting : panel mounting in a 150x31 mm panel cut-out with two screws.
3 x 2mm.
Distance between the holes 165mm
Protection: IP20.
Frontal protection: IP65 with frontal gasket mod RG-L. (optional)
Connections: Screw terminal block
2,5 mm
2
heat-resistant wiring and 6,3mm Faston
Power supply: 230Vac or. 110Vac
10%
Power absorption: 7VA max.
Display: 3 digits, red LED, 14,2 mm high.
Inputs: 3 NTC probes
Digital inputs: 2 free voltage
Relay outputs: Total current on loads MAX. 20A
compressor: relay SPST 20(8) A, 250Vac
light: relay SPST 16(3) A, 250Vac
fans: relay SPST 8(3) A, 250Vac
defrost: relay SPST 8(3) A, 250Vac
Other output : alarm buzzer
Serial output : TTL standard
Communication protocol: Modbus - RTU
Data storing: on the non-volatile memory (EEPROM).
Kind of action: 1B.
Pollution grade: normal
Software class: A.
Operating temperature: 0÷60 °C.
Storage temperature: -25÷60 °C.
Relative humidity: 20
85% (no condensing)
Measuring and regulation range: NTC probe: -40÷110°C (-58÷230°F)
Resolution: 0,1 °C or 1°C or 1 °F (selectable).
Accuracy (ambient temp. 25°C): ±0,5 °C ±1 digit
13. CONNECTIONS
13.1 XW260L
Common
Door switch
Digital inp.
Def.
Display
Room
1917 18 2320 21 22
XW260L
Def. Comp
Fan Light
Line
Neutral
5 6 7 8 9 10 11 12 13 14
20A
250Vac
MAX
20A
8A
250Vac
16A
250Vac
8A
250Vac
14. DEFAULT SETTING VALUES
SET ÷ 110°C / SET ÷ 230°F
Outputs activation delay at start up
Compressor ON time during fast freezing
Compressor ON time with faulty probe
Compressor OFF time with faulty probe
Temperature measurement unit
Resolution (integer/decimal point)
Set point for SMART DEFROST
Defrost termination temperature (1°Evaporator)
Interval between defrost cycles
(Maximum) length for 1° defrost
Displaying during defrost
MAX display delay after defrost
First defrost after start up
Defrost delay after fast freezing
Temperature alarms configuration
MAXIMUM temperature alarm
minimum temperature alarm
Temperature alarm and fan differential
Delay of temperature alarm at start up
Alarm delay at the end of defrost
Delay of temperature alarm after closing the door
Pressure switch activation number
Thermostat probe calibration
Evaporator probe calibration
Auxiliary probe calibration
Evaporator probe presence
Temperature increase during the Energy Saving
cycle
Configurable digital input polarity
Digital input configuration
EAL, bAL, PAL, dFr,
AUS, ES, OnF
Digital input alarm delay
Set point for anti-condensing heater