DVC2000 Digital Valve Controller
vi
375 Field Communicator Fast-Key Sequence (Instrument Level HC, AD and PD)
Function/Variable
Fast-Key
Sequence
Coordinates
(1)
Function/Variable
Fast-Key
Sequence
Coordinates
(1)
Actuator Style 1-2-5-2 4-E Minimum Closing Time 1-2-6-8-2 5-E
Alert Record 1-2-7-6 4-G NVM Fail 1-2-8-5 4-H
Analog Input 2 1-E Operational Status 7-3 2−F
Analog Input Calibration 1-4-1 2-E Polling Address 1-2-3-7 4-D
Analog Input Range High 1-2-4-2 4-D Pressure 6 1-E
Analog Input Range Low 1-2-4-3 4-E Pressure Calibration 1-4-4 2-E
Analog Input Units 1-2-4-1 4-D Pressure Sensor Failure 1-2-8-7 4-H
Auto Calibrate Travel 1-4-2 2-E Pressure Units 1-2-4-4 4-E
Auto Setup 1-1-1 2-B Protection Hot Key 1-A
Auto Tuner 1-1-1-3 3-B Reference Voltage Failure 1-2-8-3 4-H
Basic Setup 1-1 2-B Response Control 1-2-6 4-F
Burst 1-2-1-5 4-C Restart 1-2-1-4 3-C
Calibrate 1-4 2-E Restart Control Mode 1-2-1-3 3-C
Control Mode 1-2-1-2 3-C Secondary Electronics Revision 1-3-2-6 2-H
Custom Characteristic Table 1-2-6-5 4-F Self Test Shutdown 1-2-8 3-D
Cycle Count 1-2-7-4-4 5-H Sensor Serial Number 1-3-2-7 2-H
Cycle Count Alert 1-2-7-4 5-H Set Point Filter Time 1-2-6-6 4-F
Cycle Count Alert Enable 1-2-7-4-1 5-H Setup Wizard 1-1-1-1 3-B
Cycle Count Alert Point 1-2-7-4-2 5-H Stroke Valve 1-5 1-D
Cycle Count Deadband 1-2-7-4-3 5-H Switch 1 Closed
(2)
1-2-9−2 4-I
Damping Factor 1-1-2-3-2 4-C Switch 1 Trip Point
(2)
1-2-9-1 4-I
Date 1-2-3-4 4-D Switch 2 Closed
(2)
1-2-9-4 4-I
Descriptor 1-2-3-3 4-D Switch 2 Trip Point
(2)
1-2-9-3 4-I
Device Description Revision 1-3-3 2-D Temperature 1-3-1-1 2-G
Device Identification 1-3-2-9 2-I Temperature Comp Fail 1-2-8-2 4-H
Device Information 1-3-2 2-D Temperature Sensor Failure 1-2-8-6 4-H
Device Revision 1-3-2-2 2-H Temperature Units 1-2-4-6 4-E
Drive Alert Enable 1-2-7-5-1 5-I Transmitter Action
(2)
1-2-9-5 4-I
Drive Current Fail 1-2-8-4 4-H Transmitter Calibration
(2)
1-4-6 2-E
Drive Signal 5 1-E Travel 3 1-E
Enable Integral Control 1-2-6-9-1 5-F Travel Accumulator 1-2-7-3-4 5-H
Expert Tuning Gains 1-1-1-4-3 5-B Travel Accumulator Alert Enable 1-2-7-3-1 5-H
Failure Alerts 7-2 2-F Travel Accumulator Alert Point 1-2-7-3-2 5-H
Failure Group Enable 1-2-7-6-4-2 6-I Travel Accumulator Dead Band 1-2-7-3-3 5-H
Firmware Date 1-3-2-4 2-H Travel Alert Deadband 1-2-7-1-7 6-G
Firmware Revision 1-3-2-3 2-H Travel Alert High Point 1-2-7-1-3 6-G
Flash Rom Failure 1-2-8-1 4-H Travel Alert High High Point 1-2-7-1-5 6-G
HART Tag 1-2-3-1 4-C Travel Alert Low Point 1-2-7-1-4 6-G
HART Universal Revision 1-3-2-1 2-H Travel Alert Low Low Point 1-2-7-1-6 6-G
Input Characterization 1-2-6-4 4-F Travel Cutoff Low 1-2-6-7-4 5-E
Instrument Level 1-3-2-8 2-H Travel Cutoff High 1-2-6-7-3 5-E
Instrument Mode Hot Key 1-A Travel Deviation Alert Enable 1-2-7-2-1 5-G
Instrument Serial Number 1-2-3-6 4-D Travel Deviation Alert Point 1-2-7-2-2 5-G
Instrument Status 7 1-E Travel Deviation Time 1-2-7-2-3 5-G
Integral Dead Zone 1-2-6-9-3 5-F Travel High / Low Enable 1-2-7-1-1 6-G
Integral Gain 1-2-6-9-2 5-F Travel High High / Low Low Enable 1-2-7-1-2 6-G
Integral Settings 1-2-6-9 5-F Travel Limit High 1-2-6-7-1 5-E
Limit Switch Stat Enable 1-2-7-6-4-3 6-I Travel Limit Low 1-2-6-7-2 5-E
LUI Language 1-2-3-8 4-D Travel Sensor Failure 1-2-8-8 4-H
LUI Pressure Units 1-2-4-5 4-E Travel Setpoint 4 1-E
Main Electronics Revision 1-3-2-5 2-H Tuning Hot Key 1-A
Manual Calibrate Travel 1-4-3 2-E Tuning Set 1-1-2-3-1 4-C
Manual Setup 1-1-2 3-B Valve Group Enable 1-2-7-6-4-1 6-I
Maximum Supply Pressure 1-2-5-1 4-B Valve Style 1-2-5-3 4-E
Message 1-2-3-2 4-D Valve Serial Number 1-2-3-5 4-D
Minimum Opening Time 1-2-6-8-1 5-E Zero Control Signal 1-2-5-4 4-E
1. Coordinates are to help locate the item on the menu tree on the facing page.
2. Available only if the instrument has a transmitter and limit switches installed.