Model | DVC6000 |
---|---|
Type | Digital Valve Controller |
Manufacturer | Emerson |
Operating Temperature | -40 to 85°C (-40 to 185°F) |
Communication Protocols | HART |
Power Supply | 24 VDC |
Ingress Protection | IP66 |
Weight | Approximately 2.3 kg (5.1 lb) |
Input Signal | 4-20 mA |
Certifications | ATEX, IECEx, CSA, FM |
Mounting | Directly to valve or pipe |
Outlines manual's coverage: specs, installation, operation, maintenance for DVC6000 controllers.
Explains DVC6000 as microprocessor-based instruments converting current to pneumatic output.
Details configurations, input/output signals, and environmental conditions for the controller.
Covers CSA, FM, ATEX, IECEx classifications and safe use instructions for hazardous locations.
Instructions for mounting DVC6000 units on various actuators, including DVC6010, DVC6020, DVC6030.
Covers supply, output connections, and actuator configurations for pneumatic systems.
Details 4-20 mA loop, communication, and wiring practices for electrical setup.
Setting instrument mode to 'Out Of Service' or 'In Service' for calibration and setup.
Enabling/disabling protection, possibly requiring a jumper across auxiliary terminals.
Guides automatic setup using actuator data, controlling travel, units, and actuator specifics.
Optimizing digital valve controller tuning for better response, especially for remote units.
Setting instrument mode, control mode (Analog/Digital/Test), restart mode, and protection.
Configuring tuning sets, travel/pressure control, input characterization, and dynamic response.
Configuring electronics, sensor, environment, travel, history, SIS, and alert record settings.
Procedures for auto, manual, and touch-up calibration of valve travel for accurate positioning.
Calibrating pressure sensors (output A/B, supply) and travel sensors for accurate readings.
Adjusting the pneumatic relay, particularly for double-acting relays, for correct valve positioning.
Resetting calibration settings for sensors and tuning sets to their factory defaults.
Accessing alerts, status, device records, stroke valve, and partial stroke test functions.
Viewing instrument data like analog input, setpoint, travel, drive signal, pressure, and variables.
Displaying HART tag, Device ID, manufacturer, model, revisions, instrument level, and DD info.
Procedures for module base removal/replacement, including I/P converter, PWB, and pneumatic relay.
Steps for disassembling/reassembling travel sensors for DVC6000 and remote feedback units.
Checklist and guidance for diagnosing and resolving communication or output issues.
Guidelines for ordering replacement parts, referencing serial and part numbers.
Lists available spare parts kits like elastomer, hardware, conversion, and feedback units.
Detailed component list with key numbers and part numbers, categorized by assembly.
Explains HART protocol for digital communication over 4-20 mA loop and multidropping.
Describes DVC6000 components and signal flow from input to pneumatic output.
Provides CSA loop schematics and nameplates for DVC6010, DVC6020, DVC6030, and DVC6005.
Presents FM schematics and nameplates for DVC6010, DVC6020, DVC6030, DVC6005, DVC6015, DVC6025, DVC6035.
Details ATEX schematics and nameplates for flameproof and type n configurations.
Includes IECEx schematics and nameplates for various DVC6000 models and configurations.