Fisherr FIELDVUE™ DVC6000 Digital Valve
Controllers Instruction Manual
(Supported)
Supported products may not be manufactured again in any Emerson Process Management location under any
conditions. Spare parts availability is 7 years of best effort. Technical support is available.
Post‐sale documents (such as instruction manuals and quick start guides) are available on the CD and FishWeb. Many
are also available at www.fisher.com
.
Instruction manuals for supported products may be updated, if required, to support products in the field.
Pre‐sale documents (such as bulletins) for supported products are included on FishWeb for internal use. They are not
included on the CD.
Supported Product
D102794X012
DVC6000 Digital Valve Controllers
October 2013
Emerson Process Management
Marshalltown, Iowa 50158 USA
Sorocaba, 18087 Brazil
Chatham, Kent ME4 4QZ UK
Dubai, United Arab Emirates
Singapore 128461 Singapore
www.Fisher.com
The contents of this publication are presented for informational purposes only, and while every effort has been made to ensure their accuracy, they are not
to be construed as warranties or guarantees, express or implied, regarding the products or services described herein or their use or applicability. All sales are
governed by our terms and conditions, which are available upon request. We reserve the right to modify or improve the designs or specifications of such
products at any time without notice.
E 2013 Fisher Controls International LLC. All rights reserved.
Fisher and FIELDVUE are marks owned by one of the companies in the Emerson Process Management business unit of Emerson Electric Co. Emerson Process
Management, Emerson, and the Emerson logo are trademarks and service marks of Emerson Electric Co. All other marks are the property of their respective
owners.
Neither Emerson, Emerson Process Management, nor any of their affiliated entities assumes responsibility for the selection, use or maintenance
of any product. Responsibility for proper selection, use, and maintenance of any product remains solely with the purchaser and end user.

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Emerson Fisher FIELDVUE DVC6000 and is the answer not in the manual?

Emerson Fisher FIELDVUE DVC6000 Specifications

General IconGeneral
ModelDVC6000
TypeDigital Valve Controller
ManufacturerEmerson
Operating Temperature-40 to 85°C (-40 to 185°F)
Communication ProtocolsHART
Power Supply24 VDC
Ingress ProtectionIP66
WeightApproximately 2.3 kg (5.1 lb)
Input Signal4-20 mA
CertificationsATEX, IECEx, CSA, FM
MountingDirectly to valve or pipe

Summary

Introduction and Specifications

Scope of Manual

Outlines manual's coverage: specs, installation, operation, maintenance for DVC6000 controllers.

Description

Explains DVC6000 as microprocessor-based instruments converting current to pneumatic output.

Specifications

Details configurations, input/output signals, and environmental conditions for the controller.

Installation

Hazardous Area Classifications and Special Instructions

Covers CSA, FM, ATEX, IECEx classifications and safe use instructions for hazardous locations.

Mounting Guidelines

Instructions for mounting DVC6000 units on various actuators, including DVC6010, DVC6020, DVC6030.

Pneumatic Connections

Covers supply, output connections, and actuator configurations for pneumatic systems.

Electrical Connections

Details 4-20 mA loop, communication, and wiring practices for electrical setup.

Basic Setup

Instrument Mode

Setting instrument mode to 'Out Of Service' or 'In Service' for calibration and setup.

Configuration Protection

Enabling/disabling protection, possibly requiring a jumper across auxiliary terminals.

Setup Wizard

Guides automatic setup using actuator data, controlling travel, units, and actuator specifics.

Using the Performance Tuner

Optimizing digital valve controller tuning for better response, especially for remote units.

Detailed Setup

Mode and Protection

Setting instrument mode, control mode (Analog/Digital/Test), restart mode, and protection.

Response Control

Configuring tuning sets, travel/pressure control, input characterization, and dynamic response.

Alert Setup

Configuring electronics, sensor, environment, travel, history, SIS, and alert record settings.

Calibration

Travel Calibration

Procedures for auto, manual, and touch-up calibration of valve travel for accurate positioning.

Sensor Calibration

Calibrating pressure sensors (output A/B, supply) and travel sensors for accurate readings.

Relay Adjust

Adjusting the pneumatic relay, particularly for double-acting relays, for correct valve positioning.

Restore Factory Settings

Resetting calibration settings for sensors and tuning sets to their factory defaults.

Viewing Device Variables and Diagnostics

Service Tools

Accessing alerts, status, device records, stroke valve, and partial stroke test functions.

Overview

Viewing instrument data like analog input, setpoint, travel, drive signal, pressure, and variables.

Device Information

Displaying HART tag, Device ID, manufacturer, model, revisions, instrument level, and DD info.

Maintenance and Troubleshooting

Module Base Maintenance

Procedures for module base removal/replacement, including I/P converter, PWB, and pneumatic relay.

Travel Sensor Maintenance

Steps for disassembling/reassembling travel sensors for DVC6000 and remote feedback units.

Troubleshooting

Checklist and guidance for diagnosing and resolving communication or output issues.

Replaceable Parts

Parts Ordering

Guidelines for ordering replacement parts, referencing serial and part numbers.

Parts Kits

Lists available spare parts kits like elastomer, hardware, conversion, and feedback units.

Parts List

Detailed component list with key numbers and part numbers, categorized by assembly.

Appendix A: Principle of Operation

HART Communication

Explains HART protocol for digital communication over 4-20 mA loop and multidropping.

DVC6000 Operation

Describes DVC6000 components and signal flow from input to pneumatic output.

Appendix B: Loop Schematics/Nameplates

CSA Loop Schematics and Nameplates

Provides CSA loop schematics and nameplates for DVC6010, DVC6020, DVC6030, and DVC6005.

FM Loop Schematics and Nameplates

Presents FM schematics and nameplates for DVC6010, DVC6020, DVC6030, DVC6005, DVC6015, DVC6025, DVC6035.

ATEX Loop Schematics and Nameplates

Details ATEX schematics and nameplates for flameproof and type n configurations.

IECEx Loop Schematics and Nameplates

Includes IECEx schematics and nameplates for various DVC6000 models and configurations.