EasyManua.ls Logo

Emerson Fisher FIELDVUE DVC6005 Series - Page 17

Emerson Fisher FIELDVUE DVC6005 Series
30 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Quick Start Guide
D103784X012
DVC6005 Digital Valve Controllers
March 2018
17
WARNING
Personal injury or property damage can occur from cover failure due to overpressure. Ensure that the housing vent
opening is open and free of debris to prevent pressure buildup under the cover.
This unit vents the supply medium into the surrounding atmosphere. When installing this unit in a nonhazardous
(nonclassified) location in a confined area, with natural gas as the supply medium, you must remotely vent this unit to a
safe location. Failure to do so could result in personal injury or property damage from fire or explosion, and area
reclassification.
When installing this unit in a hazardous (classified) location remote venting of the unit may be required, depending upon
the area classification, and as specified by the requirements of local, regional, and national codes, rules and regulations.
Failure to do so when necessary could result in personal injury or property damage from fire or explosion, and area
reclassification.
In addition to remote venting of the unit, ensure that all caps and covers are correctly installed. Failure to do so could result
in personal injury or property damage from fire or explosion, and area reclassification.
3. If necessary, remove the plastic vent on the DVC6005 and install a pipeaway vent line using at least 12.7 mm
(1/2inch) diameter tubing. The vent line must be as short as possible with a minimum number of bends and elbows
to prevent back pressure buildup.
Figure 14. Vent Connection
PLASTIC EXHAUST
VENT (3/8 NPT)
X0437

Related product manuals