65
IECEx
Flameproof
WARNING
Do not open while energized.
Potential electrostatic charging hazard. See warning on page 3.
DVC6200 and DVC6205 Series (HART HW1 & HW2, SIS, FOUNDATION FIELDBUS, PROFIBUS)
Ex d IIC T5 (Ta ≤ 80°C) / T6 (Ta ≤ 75°C)
30 V max, 20 mA
IP66
DVC6215 Remote Mount
Ex d IIC T4 (Ta ≤ 125_C) / T5 (Ta ≤ 95_C) / T6 (Ta ≤ 80_C)
30 V max, 20 mA
IP66
Type n
WARNING
Do not open while energized.
Potential electrostatic charging hazard. See warning on page 3.
DVC6200 and DVC6205 Series (HART HW1 & HW2, SIS, FOUNDATION FIELDBUS, PROFIBUS)
Ex nC IIC T5 (Ta ≤ 80_C) / T6 (Ta ≤ 75_C)
30 V max, 20 mA
IP66
DVC6215 Remote Mount
Ex nA IIC T4 (Ta ≤ 125_C) / T5 (Ta ≤ 95_C) / T6 (Ta ≤ 80_C)
30 V max, 20 mA