i2P-100 Transducer
Instruction Manual
Form 5777
September 2004
2
Table 1. Specifications
Input Signal
(1)
Available as standard with 4-20 mA.
User configurable by dip switch for split ranging,
see table below.
Output Signal
(1)
Available as standard 0.2 to 1.0 bar (3 to 15 psig)
or 0.4 to 2.0 bar (6 to 30 psig). User configurable
by dip switch selection and zero and span
potentiometer adjustment, see table below.
INPUT SIGNAL
OUTPUT PRESSURE
INPUT SIGNAL
BAR
PSIG
4to20mAdc
0.2 to 1.0 3 to 15
4 to 20 mA dc
0.4 to 2.0 6 to 30
4 to 12 mA dc 0.2 to 1.0 3 to 15
12 to 20 mA dc 0.2 to 1.0 3 to 15
Equivalent Circuit
The Type i2P-100 equivalent circuit is a series
circuit consisting of a constant voltage drop
(battery) of approximately 4 V dc and a total
resistance of 40 ohms. Input is shunted by two
6.8 V zener diodes (see figure 9).
Supply Pressure
(1,5)
Recommended: 0.3 bar (5 psi) higher than upper
range limit of output signal
Maximum: 3.4 bar (50 psig)
Medium: Air or Natural Gas
(4)
Average Steady State Flow Rate
(1)(2)
OUTPUT RANGE
0.2 to 1.0 bar (3-15 psig) 0.4 to 2.0 bar (6-30 psig)
SUPPLY PRESSURE
1.5 bar (20 psig) 2.4 bar (35 psig)
OUTPUT FLOW RATE OUTPUT FLOW RATE
Bar Psig
Normal
m
3
/h
Scfh Bar Psig
Normal
m
3
/h
Scfh
0.2 3 0.08 3.0 0.4 6 0.09 3.6
0.6 9 0.12 4.5 1.2 18 0.19 7.0
1.0 15 0.17 6.3 2.1 30 0.27 10.2
Maximum Output Air Capacity
(2)
8.0 m
3
/hr (5.0 scfm) at 1.4 bar (20 psig) supply
pressure
Performance
(3)
Reference Accuracy: ±1.0% of full scale output
span; includes combined effects of hysteresis,
linearity, and deadband
Independent Linearity
(1)
: ±0.75% of full scale
output span
Hysteresis
(1)
: 0.4% of full scale output span
Frequency Response
(1)
: Gain is attenuated 3 dB
at 6 Hz with transducer output signal piped to a
typical instrument input
Temperature Effect: ±0.14% per degrees
Celsius (±0.75% per degrees Fahrenheit) of span
Supply Pressure Effect: 0.2% of full scale output
span per bar supply pressure change (0.2% of
full scale output span per psi supply pressure
change)
Vibration Effect: Less than 1% of full scale
output span when tested to SAMA PMC 31.1,
Condition 3
Electromagnetic Interference (EMI)
(1)
: Tested
per IEC 61326-1 (Edition 1.1).Conforms to the
European EMC Directive. Meets emission levels
for Class A equipment (industrial locations) and
Class B equipment (domestic locations). Meets
immunity requirements for industrial locations
(Table A.1 in the IEC specification document).
Immunity performance shown in table 2.
Operating Ambient Temperature Limits
(5)
-40 to 85_C (- 40 to +180_F)
Electrical Classification
Hazardous Area
(6)
:
Explosion proof, Dust-Ignition proof, DIV 2,
Intrinsically Safe
Explosion proof, Non-incendive,
Dust-Ignition proof, Intrinsically Safe
Intrinsically Safe, Type n and Flameproof
Intrinsically Safe, Type n and Flameproof
Approved for use with natural gas
(4)
(continued)
APPROVED
ATEX
(LCIE)
IECEx
(CSA)