EasyManua.ls Logo

Emerson QUIET KOOL EAPC14RD1 - User Manual

Emerson QUIET KOOL EAPC14RD1
20 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
EMERSON
QUIET KOOL
OWNER'S MANUAL
PORTABLE AIR CONDITIONER
Please read this manual carefully before operating your appliance and retain it for future reference.
MODEL: EAPC12RD1
EAPC14RD1

Questions and Answers

Summary

IMPORTANT SAFETY INSTRUCTIONS

Basic Safety Precautions

General guidelines to prevent fire, electric shock, or personal injury during use.

Electrical Safety Precautions

Essential safety measures regarding grounding, wiring, and power cord integrity.

PARTS AND FEATURES

Key Components Identification

Visual identification and listing of all major physical parts of the air conditioner.

Control Panel Layout and Functions

Explanation of buttons, indicators, and their functions on the unit's control panel.

OPERATING INSTRUCTIONS

Unit Control Panel Operation

How to operate the air conditioner using its on-unit control panel for modes and settings.

Remote Control Operation Guide

Instructions for using the remote control, including features and operational modes.

INSTALLATION GUIDELINES

Preparing for Air Exhaust Installation

Steps for unit placement and setting up the exhaust hose for hot air.

Window Slider Kit Installation

Detailed instructions for fitting the window slider panel into different window types.

Continuous Water Drainage Setup

Guidance on connecting a hose for continuous draining of condensate.

CARE AND CLEANING PROCEDURES

Cleaning the Air Conditioner Unit

Methods for cleaning the exterior cabinet and front panel of the appliance.

Air Filter Cleaning and Maintenance

Steps to clean the air filters for efficient operation and longevity.

Preparing for Winter Storage

Instructions on how to properly store the unit when not in use for extended periods.

TROUBLESHOOTING COMMON ISSUES

Problem Diagnosis and Solutions

A guide to identifying and resolving common operational problems before seeking service.

Overview

This document is the owner's manual for the EMERSON QUIET KOOL Portable Air Conditioner, models EAPC12RD1 and EAPC14RD1. It provides comprehensive information regarding the appliance's function, safety, operation, installation, and maintenance.

Function Description:

The EMERSON QUIET KOOL Portable Air Conditioner is designed to provide high-efficiency cooling with the added convenience of portability. It is intended for normal household use and is capable of cooling a designated area by exhausting warm air outside through a window kit. The unit features multiple operating modes including Cool, Dry, Fan, and ECO (energy saver) mode, allowing users to select the most suitable setting for their comfort needs. It also includes a timer function for scheduled operation and a sleep mode for optimized overnight cooling.

Important Technical Specifications:

While specific numerical technical specifications like BTU ratings or power consumption are not explicitly listed in the provided pages, the manual does highlight several important operational and electrical requirements:

  • Electrical Safety: The unit must be plugged into its own grounded circuit (15 Amp, 60 Hz, 115 V AC circuit) and protected by a 13-amp time delay fuse or circuit breaker. It features a built-in circuit breaker on the power cord with TEST and RESET buttons, which should be tested periodically.
  • Weight Capacity: The appliance should be installed on a sturdy, level floor capable of supporting up to 110 lbs (50 kg).
  • Operating Temperature: Do not operate the appliance if the room temperature is lower than 41°F (5°C) to prevent coils from freezing.
  • Clearance: A minimum of 12 inches clearance around the unit is required for proper installation and airflow.
  • Exhaust Hose: The exhaust hose can be extended from its original length of 15 inches up to 59 inches, but it is recommended to keep the length to the minimum required and avoid sharp bends or sags.
  • Remote Control Range: The remote control must be no more than 16 ft (5 meters) away from the unit, without obstacles.
  • Error Codes: The unit displays error codes for specific issues: "AS" for room temperature sensor failure, "ES" for pipe temperature sensor failure, and "P1" for a full water collection tank.

Usage Features:

The portable air conditioner offers a user-friendly experience with both a control panel on the unit and a remote control.

  • Control Panel: The control panel allows for power on/off, mode selection (Cool, Dry, Fan, ECO), temperature adjustment, fan speed selection (Hi, Med, Low, Auto), and timer settings. It also has a filter reset indicator.
  • Remote Control: The remote control duplicates most of the functions available on the control panel, including power on/off, mode selection, temperature increase/decrease, fan speed, timer, sleep mode, and °C/°F display toggle. It uses two "AAA" 1.5V batteries.
  • Operating Modes:
    • Cool Mode: Provides cooling with adjustable fan speed and desired temperature.
    • Dry Mode: Dehumidifies the air; fan speed is automatically set to "low" and cannot be adjusted. The air exhaust hose does not need to be connected in this mode.
    • Fan Mode: Circulates air without cooling; fan speed can be set to "hi", "med", "low", or "auto". The air exhaust hose does not need to be connected.
    • ECO Mode: An energy-saving mode where the fan continues to run for 3 minutes after the compressor shuts off, then cycles on for 90 seconds at 10-minute intervals until the room temperature rises above the set temperature, at which point the compressor restarts.
    • Timer Mode: Allows programming of both "Timer ON" (scheduled startup) and "Timer OFF" (scheduled shutdown) in 0.5-hour increments up to 10 hours, then 1-hour increments up to 24 hours.
    • Sleep Mode: Optimizes cooling for sleep by automatically setting fan speed to "low". In Cool or ECO mode, the set temperature increases by 1°F after 60 minutes, and again after another 60 minutes, maintaining this new temperature for 6 hours before returning to the original setting.
    • Louver Swing Function: Enables the top panel louver to swing up and down for better air distribution.
  • Installation: The manual provides detailed instructions for installing the exhaust hose and window slider kit in both double-hung sash windows and sliding sash windows. It emphasizes ensuring proper sealing to maximize efficiency.
  • Continuous Drainage: For Dry mode, a garden hose (sold separately) can be connected to the continuous drain outlet to drain condensate.

Maintenance Features:

Regular maintenance is crucial for the appliance's efficient operation and longevity.

  • Cleaning the Unit: The cabinet and front should be dusted with an oil-free cloth or washed with a cloth dampened in a solution of warm water and mild liquid dishwashing detergent. Harsh cleaners, wax, or polish should be avoided. Care must be taken to prevent excess water from entering controls.
  • Cleaning the Filters: The air filter should be cleaned every two weeks. It can be washed with liquid dishwashing detergent and warm water, rinsed thoroughly, and allowed to dry completely, or vacuumed clean. The filter indicator on the control panel illuminates after 250 hours of operation as a reminder and can be reset by holding the "fan speed" button for 5 seconds.
  • Emptying the Water Collection Tank: When the "P1" error code appears, the internal water collection tank is full and needs to be drained. Instructions are provided for draining excess water, including during winter storage.
  • Winter Storage: For extended periods of non-use, the unit should be completely drained of water, the filter cleaned and reinstalled, batteries removed from the remote control, and the unit stored in a cool, dry location away from direct sunlight, extreme temperatures, and excessive dust.
  • Pre-use Check: Before using the air conditioner again after storage, ensure the filter and drain cap are in place, check the power cord for damage, install new batteries in the remote control, and follow installation instructions.

Emerson QUIET KOOL EAPC14RD1 Specifications

General IconGeneral
BrandEmerson
ModelQUIET KOOL EAPC14RD1
CategoryAir Conditioner
LanguageEnglish

Related product manuals