Precision Cooling
For Business-Critical Continuity™
Liebert Deluxe System/3
Operation and Maintenance Manual
50 and 60 Hz, 6-30 Ton DX Systems (DH/DE/VH/VE); 12-60 Ton CW Systems (FH/UH)

Table of Contents

Questions and Answers

  • K
    Kathy BarnesAug 13, 2025
    What to do if my Emerson Liebert Deluxe System/3 DE Air Conditioner compressor will not start?
    • B
      Brittney WestAug 13, 2025
      If the Emerson Air Conditioner compressor won't start, verify the main switch, fuses, circuit breakers, and wiring. If there's a current overload, reset it manually. Also, ensure all electrical connections are tight. If the compressor motor is burned out, it should be checked and replaced if found defective.
  • L
    lauren49Aug 16, 2025
    What to do if Emerson Air Conditioner compressor will not operate, contactor not pulling in?
    • E
      Elizabeth PhillipsAug 16, 2025
      If your Emerson Air Conditioner compressor won't operate and the contactor isn't pulling in, start by checking the monitor status to ensure there's a call for cooling. Next, hold a screwdriver over the solenoid to check for a magnetic field, indicating it's energized. Finally, check the gas pressure to ensure the low-pressure switch is making contact; you might need to manually energize the low-pressure switch.
  • J
    Jeffrey WeissAug 20, 2025
    How to troubleshoot Emerson Air Conditioner blower that will not start?
    • J
      Jennifer CraigAug 20, 2025
      If the Emerson Air Conditioner blower doesn't start, first check L1, L2, and L3 for the rated voltage to ensure there's main power. Then, inspect the fuses or circuit breakers related to the main fan. If overloads have tripped, push the reset button on the main fan overload and check the amp draw. Check for 24 VAC between P24-2 and P24-1 to see if there's output voltage from the transformer; if not, check the primary voltage. Also, check for 24 VAC between P4-4 and E1 for the control fuse; if there's no voltage, check for a short and replace the fuse or reset the circuit breaker. For SM models only, jumper P9-1 to P9-2 to test the start switch. If the unit starts and stops after removing the jumper, replace S1.
  • C
    Carol LopezAug 25, 2025
    Why Emerson Air Conditioner blower runs but controls will not operate?
    • C
      Christine SalazarAug 25, 2025
      If the blower runs but the controls of your Emerson Air Conditioner do not operate, then check for 24 VAC between P36-9 and P36-10. If voltage is not present, R1 is not receiving power. Check air switch by jumpering P36-4 to P36-7. If R1 closes, the air switch is not closing (check for blower rotation, loose wiring, and pinched tubing.) Remove jumper. Check for 24 VAC at R1 coil. If the voltage is present and R1 is not pulling, replace R1.
  • D
    Daniel LesterAug 28, 2025
    Why is my Emerson Air Conditioner compressor noisy?
    • B
      Brian DiazAug 28, 2025
      If the Emerson Air Conditioner compressor is noisy, the issue might be slugging due to refrigerant floodback (see symptom: flooding). It could also be due to wiped bearings from oil loss (see Oil Pressure and check for a defective oil failure control). Loose compressor or piping supports can also cause noise, so tighten the clamps. If there are broken connecting rods, valves, or other running gear, replace the compressor.
  • K
    Kenneth WatsonSep 4, 2025
    Why is there excessive leakage around the Emerson Liebert Deluxe System/3 DE pump shaft?
    • R
      Rick RamirezSep 4, 2025
      If you observe excessive leakage around the pump shaft of your Emerson Air Conditioner while it's operating, it's likely due to a worn seal or packing, which will need to be replaced.
  • B
    barroncrystalSep 7, 2025
    What causes the Emerson Liebert Deluxe System/3 DE humidifier contactor not to be pulled in?
    • T
      Thomas AdamsSep 8, 2025
      If the Emerson Air Conditioner humidifier contactor is not pulled in, it could be due to a full cylinder or an activated interface. Refer to similar symptoms for solutions. The canister may also be expired, requiring replacement. Alternatively, there might be a problem with the fill water system, such as the water supply not being on, a fill valve issue, or a drain valve stuck open.
  • A
    Alyssa SalinasDec 1, 2025
    What to do if red LED is on on Emerson Liebert Deluxe System/3 DE Air Conditioner humidifier control board?
    • M
      michaelchangDec 1, 2025
      If the red LED on the Emerson Air Conditioner humidifier control board is on and the humidifier contactor isn't pulled in, it could be due to several reasons: The humidifier amps may have reached 138% of full load, indicating a canister expiration (replace the canister). DIP switch settings might have been changed with water in the canister (drain the canister and contact Liebert service). A stuck-open humidifier fill valve should be checked. High water conductivity could also be the cause (check water conductivity/quality and contact Liebert service). Incorrect DIP switch settings should be verified (refer to Circuit Board Adjustments on page 62). Mineral deposits obstructing the drain valve should be checked and cleaned if necessary. A faulty solenoid can be identified by checking for a ...

Summary

Introduction to Liebert Deluxe Systems

System Description

Overview of Liebert Deluxe environmental control system configurations and operational differences.

Initial Start-Up Procedure

Additional Considerations for Upflow Units

Specific adjustments for upflow units including sheave selection for airflow.

Advanced Microprocessor Controls Setup

Basics of AM Control

Introduction to control keys, unit operation, and alarm handling for AM control.

Main Menu Navigation (AM Control)

Explains access to Main Menu and its primary selections like Status, Setpoints, and Date/Time.

Status and Alarm Data

Details on viewing active alarms, operating status, alarm history, run hours, and analog sensors.

Setpoints and System Setup

Covers viewing setpoints, system configuration, diagnostics, and password changes.

Load Control Features

Explanation of short cycle, sequential load activation, and compressor sequencing.

Control Circuit Board Overview

Description of the control board components like LCD contrast, memory, and DIP switches.

Communications with AM Control

Details on monitoring and changing functions via communication ports.

Advanced Microprocessor with Graphics Control Setup

Basics of AG Control

Introduction to AG control keys, unit operation, and alarm management.

Main Menu Navigation (AG Control)

Guides users through the AG control's Main Menu structure and options.

Status Display (AG Control)

Information on interpreting the AG control's status screen graphics and data.

Alarms Management (AG Control)

Covers active alarms, history log, and setup for alarms and custom messages.

Operating Status and Setpoints

Viewing operational status and managing control setpoints and parameters.

System Setup and Configuration

Options for system operation, sensor calibration, and control algorithm selection.

Run Diagnostics (AG Control)

Procedures for testing system inputs, outputs, and the control board.

Analog;Digital Inputs Configuration

Details on reading and setting up analog and digital inputs for sensors.

Load Control Features (AG Control)

Explanation of load control logic including compressor sequencing.

Response by Control Type

Temperature Control

How different control types (Proportional, PID, Intelligent) affect temperature management.

Humidity Control

Details on humidity control algorithms and dehumidification/humidification operations.

Load Control Features

Mechanisms for managing system loads like short cycling and compressor sequencing.

Analog Sensors

Information on connecting and configuring analog sensors for system monitoring.

Alarm Descriptions and Solutions

Standard Alarms

Definitions and troubleshooting for common unit alarms like filter changes and compressor overloads.

Optional and Custom Alarms

Descriptions for alarms related to optional features and user-defined custom alarms.

Component Operation and Maintenance

System Testing Procedures

How to test cooling, heating, humidification, and dehumidification functions.

Filters Maintenance

Guidelines for checking and replacing air filters to maintain system efficiency.

Blower Package Maintenance

Inspection and maintenance for blower components like impellers, bearings, and belts.

Refrigeration System Checks

Maintenance for compressor oil, pressures, superheat, and expansion valves.

Humidifier Maintenance

Procedures for maintaining infrared and steam generating humidifiers.

Troubleshooting Guide

Blower System Troubleshooting

Diagnosing and resolving issues with the unit's blower system.

Chilled Water System Troubleshooting

Diagnosing and resolving issues with chilled water valves and actuators.

Compressor and Refrigeration Troubleshooting

Troubleshooting common problems related to compressors and refrigeration systems.

Dehumidification Troubleshooting

Diagnosing and resolving issues with the dehumidification process.

Humidifier Troubleshooting

Resolving problems with steam generator and infrared humidifiers.

Emerson Liebert Deluxe System/3 DE Specifications

General IconGeneral
BrandEmerson
ModelLiebert Deluxe System/3 DE
CategoryAir Conditioner
LanguageEnglish