Liebert.CRV+ Series Air Cooled Precision Air Conditioner
User Manual
Original Instruction
Version V1.4
Revision date March 4, 2015
BOM 31012977
Emerson Network Power provides customers with technical support. Users may contact the nearest
Emerson local sales office or service center.
Copyright © 2014 by Emerson Network Power Co., Ltd.
All rights reserved. The contents in this document are subject to change without notice.
Emerson Network Power Co., Ltd.
Address: Block B2, Nanshan I Park, No.1001 Xueyuan Road, Nanshan District, Shenzhen 518055, P.
R. China
Homepage: www.emersonnetworkpower.com.cn
E-mail: overseas.support@emerson.com

Table of Contents

Questions and Answers

  • P
    Patricia BlairAug 18, 2025
    How to fix Emerson Liebert.CRV Air Conditioner EC fan that won’t start?
    • H
      hoffmanmichelleAug 18, 2025
      If the EC fan of your Emerson Air Conditioner won’t start, check that the fan MCB is closed and that the power voltage of each phase is normal. Also, check J15 on the micro-processing control board to determine if the control board is faulty. Inspect the alarm lamp on the fan power module to see if it is faulty. Finally, check L1, L2, and L3 of the fan against power failure, phase loss, and low voltage; verify that the analog output is within the required range of 0 ~ 10Vdc; check if the motor is clogged or too hot; and look for hall failure. Clear any faults, cut off the fan power to cool the motor if it's too hot before powering it on again and if hall failure occurs, the factory service is required.
  • J
    James KirbyAug 20, 2025
    What to do if Emerson Liebert.CRV Air Conditioner heating system doesn't start?
    • Y
      youngchelseaAug 20, 2025
      If the heating system of your Emerson Air Conditioner does not start and the contactor does not close, check the state of the micro-processing controller to confirm if a heating command is required. Also, use a multimeter to measure the resistance on both ends of the temperature controller. If the resistance is very large, it indicates that the safety device may be open. Then check if the fuse is open and if the temperature controller is damaged. Measure the resistance of the heater with an ohmmeter to judge if the heater is damaged.
  • S
    shannonchristensenAug 23, 2025
    How to fix Emerson Air Conditioner compressor over-temperature?
    • A
      ariasdebraAug 23, 2025
      If your Emerson Air Conditioner compressor is over-temperature, it could be due to a too high compression ratio. Check the settings of the HP switch and LP switch, and make sure whether the condenser is clogged. Check that the fans of the evaporator and condenser are normal. Also, it might be caused by a too high suction overheat degree, so regulate the electronic expansion valve or add the proper amount of refrigerant.
  • C
    Charles GallegosAug 26, 2025
    What to do for high pressure protection on Emerson Liebert.CRV?
    • S
      Sara DavidsonAug 26, 2025
      If your Emerson Air Conditioner is experiencing high pressure protection issues, the condenser may be clogged, so clean it. Also, check the condensing fan for air-cooled systems to ensure the condenser system starts. Too much refrigerant may have been charged, so verify whether the subcooling degree is too high.
  • D
    Dr. Teresa Collins PhDAug 28, 2025
    Why my Emerson Liebert.CRV Air Conditioner compressor won’t start?
    • J
      James WoodwardAug 28, 2025
      The compressor on your Emerson Air Conditioner may not start due to several reasons. First, check the main power for undervoltage, overvoltage, and phase loss. Second, inspect the compressor MCB, contactor, and connecting cables for faults. Third, view the unit alarm records, replace any damaged components, and power it on again. Finally, the compressor coils might be shorted and burnt, so inspect the motor and replace it if you find any defects.
  • C
    Claudia BarnesAug 30, 2025
    What to do if Emerson Air Conditioner has low suction pressure?
    • M
      Monica PetersonAug 31, 2025
      If your Emerson Air Conditioner has low suction pressure or liquid returned, several issues could be the cause. Begin by checking for refrigerant leaks, sealing any leaking points, and adding refrigerant. Next, replace the air filter if it's dirty, or replace the filter drier if it's clogged. Also, check the control board of the electronic expansion valve for improper superheating degree and replace the sensing element if it's faulty. Ensure proper airflow distribution by checking the air supply and return system and verify the condenser isn't faulty due to low condensing pressure.
  • K
    kenneth57Sep 2, 2025
    What to do if contactor does not close and compressor does not start in Emerson Liebert.CRV?
    • C
      coryhuntSep 2, 2025
      If the contactor doesn't close and the compressor doesn't start in your Emerson Air Conditioner, check the state of the micro-processing controller for a low discharging overheat degree alarm. Also, check for a high pressure (HP) alarm and refer to Chapter 5. Verify if a discharging low/high temperature alarm exists, and check the history alarm for a low pressure alarm. Ensure the contactor is able to energize and check the compressor driver. Finally, see if the compressor coil is open circuit; if it is, wait until the coil cools down to restore it automatically.
  • M
    Michael SmithSep 4, 2025
    Why does my Emerson Liebert.CRV compressor stop after 3 minutes?
    • D
      Donald ColemanSep 4, 2025
      If your Emerson Air Conditioner's compressor stops after running for 3 minutes and the contactor opens, it could be due to refrigerant leakage causing a low or abnormal low pressure check. Verify the suction pressure, check the circuit of the low pressure sensor, and calibrate the low pressure sensor reader to ensure it's within ±0.3bar range of the actual pressure.
  • J
    Jeremy ParksSep 7, 2025
    Why is heating ineffective when contactor closes in Emerson Liebert.CRV Air Conditioner?
    • B
      brittney91Sep 7, 2025
      If the contactor closes but heating is ineffective in your Emerson Air Conditioner, the heater's main power may be off. Check if the heater's MCB is turned ON and verify that L1, L2, and L3 voltages are normal when the contactor is energized. Also, the electric heater might be burned, so turn off the power and physically check its condition.
  • K
    Kimberly BautistaSep 9, 2025
    Why is my Emerson Air Conditioner compressor so noisy?
    • G
      greenaustinSep 10, 2025
      If your Emerson Air Conditioner compressor is too noisy, it could be due to liquid returned. Refer to the handling methods of ‘Low suction pressure or liquid returned.’ It may also be because the bearing is worn out due to lubricant loss, so add lubricant.

Summary

Chapter 1 Overview

Product Introduction

Overview of the Liebert.CRV+ Air Cooled AC unit's features, applications, and design.

Nomenclature of the CRV+ Air Cooled AC Unit

Explanation of the model naming convention and its constituent parts.

Appearance

Visual description of the CRV+ air conditioner's external design and form.

Main Components Of Indoor Unit

Identification and brief description of key internal components within the indoor unit.

Refrigerant Requirement

Specifications for the approved refrigerant type, quality, and handling.

Chapter 2 Instruction For Pre-installation

Equipment Room Consideration

Requirements for the installation environment, including damp proofing and sealing.

Space Clearance For Maintenance

Required clearances around the unit for effective operation and maintenance access.

Environmental Requirements

Guidelines for optimal operating and storage conditions to ensure performance.

Movement, Unpacking And Inspection

Procedures for safely moving, unpacking, and inspecting the unit upon arrival.

Chapter 3 Machanical Installation

Installation Notes

Essential guidelines and considerations for a proper and safe mechanical installation.

System Arrangement

Diagrams and explanations of the overall system layout and component connections.

Installation Procedures

Step-by-step instructions for the physical mounting and connection of the unit.

Piping

Guidance on connecting refrigerant, drain, and water lines according to specifications.

Removing Transportation Fastener And Vibration Absorber

Instructions for removing protective elements and preparing the unit for operation.

Checklist For Completed Installation

A final verification list to confirm all mechanical installation tasks are done.

Chapter 4 Electrical Installation

Task Introduction

Overview of electrical installation requirements, wiring, and safety precautions.

Connecting Cables Of Indoor Unit

Detailed steps for connecting power, control, and sensor cables to the indoor unit.

Checklist For Completed Installation

Final inspection of electrical connections and components before system power-up.

Chapter 5 System Power-On Commissioning

Location Of MCBs

Identification of main circuit breaker positions for system power management.

Power-On Commissioning

Procedures for safely energizing, testing, and verifying the system's initial operation.

Checklist For Completed Commissioning

Post-commissioning checks to confirm all system functions are operational.

Chapter 6 Micro-Processing Controller

Feature

Highlights of the micro-processing controller's capabilities, including user interface and protection functions.

Appearance

Description of the controller's physical layout, display screen, and control buttons.

LCD Screen

Explanation of the controller's display interface, showing operating status and parameters.

Control Button

Details the function and operation of each button on the micro-processing controller.

Control Screen

Description of the various screens presented by the controller during operation and setup.

Menu Structure

Overview of the controller's menu hierarchy, navigation, and parameter settings.

Chapter 7 System Operation And Maintenance

Routine Maintenance And Inspection(monthly)

Scheduled monthly tasks for checking and maintaining system components.

Routine Maintenance And Inspection (Half yearly)

Semi-annual inspection procedures to ensure continued system reliability.

Self-Diagnosing Functions

Explanation of the controller's built-in diagnostic capabilities for fault detection.

Electric Control Part

Maintenance guidelines for electrical connections, components, and control systems.

Air Filter Maintenance Guidance

Instructions for inspecting, cleaning, or replacing the unit's air filters.

Fan Kit Maintenance Guidance

Procedures for checking and maintaining the fan assembly and its components.

Electrode Humidifier Maintenance Guidance

Maintenance and replacement procedures for the electrode humidifier unit.

Electrical Heater Maintenance Guidance

Guidelines for periodic inspection and maintenance of the electric heater.

Refrigerating System Maintenance Guidance

Checks and maintenance for the refrigeration cycle components, pressures, and refrigerant.

Drainage System Maintenance Guidance

Inspection of the water tray and drainage system for proper function and cleanliness.

Chapter 8 Troubleshooting

Troubleshooting of Fan

Common fan issues, their possible causes, and recommended troubleshooting steps.

Troubleshooting of Heating System

Identification and resolution of problems related to the heating system's operation.

Troubleshooting of Compressor and Cooling System

Diagnosis and remedies for common compressor and cooling system faults.

Appendix 1 Circuit Diagram

CR035 Circuit Diagram

Electrical schematic detailing the wiring and connections for the CR035 model.

CR025 Circuit Diagram

Electrical schematic detailing the wiring and connections for the CR025 model.

Appendix 2 Menu Structure Of Micro-Processing Controller

Micro-Processing Controller Menu Navigation

Visual representation of the controller's menu hierarchy and navigation paths.

Emerson Liebert.CRV+ Series Specifications

General IconGeneral
BrandEmerson
ModelLiebert.CRV+ Series
CategoryAir Conditioner
LanguageEnglish