June 2016
8
Quick Start Guide
Product Certifications
European Directive information
A copy of the EC Declaration of Conformity can be found at the end of the Quick
Start Guide. The most recent revision of the EC Declaration of Conformity can be
found at EmersonProcess.com/Rosemount
.
Hazardous locations certifications
USA
E5 FM Explosion-proof and Dust-Ignition-proof
Certificate: 0R7A2.AE
Standards: FM Class 3600: 2011; FM Class 3611: 2004; FM Class 3615: 2006; FM Class
3810: 2005; ANSI/NEMA
®
- 250: 1991
Markings: XP CL I, Div 1, GP B, C, D; DIP CL II/III, Div 1, GP E, F, G; T6(–50 °C ≤ T
a
≤
+155 °C); Type 4X
Canada
E6 CSA Explosion-proof and Dust-Ignition-proof
Certificate: 1063635
Standards: CSA C22.2 No. 0-M91; CSA C22.2 No. 25-1966; CSA C22.2 No. 30-M1986;
CSA C22.2 No. 94-M91; CSA C22.2 No. 142-M1987; CSA C22.2 No.
213-M1987
Markings: XP CL I, Div 1, GP B, C, D; DIP CL II/III, Div 1, GP E, F, G; CL I, Div 2, GP A, B, C, D;
(-50 °C ≤ T
a
≤ +85 °C)
Europe
E1 ATEX Flameproof
Certification number: FM12ATEX0065X
Standards: 60079-0:2012; EN60079-1:2007
Markings: II 2 G Ex d IIC T6...T1 Gb, T6(-50 °C ≤ T
a
≤ +40 °C), T5...T1 (-50 °C ≤ T
a
≤
+60 °C),
1180
Special Conditions for Safe Use (X):
1. See certificate for ambient temperature range.
2. The non-metallic label may store an electrostatic charge and become a source of
ignition in Group III environments.
3. Guard the LCD display cover against impact energies greater than 4 joules.
4. Consult the manufacturer if dimensional information on the flameproof joints is
necessary.
5. A suitable certified Ex d or Ex tb enclosure is required to be connected to temperature
probes with Enclosure option "N".
6. Care shall be taken by the end user to ensure that the external surface temperature
on the equipment and the neck of DIN Style Sensor probe does not exceed 130 °C.