Do you have a question about the Emerson Rosemount 214C and is the answer not in the manual?
Category | Accessories |
---|---|
Model | 214C |
Process Connection | Threaded or Flanged |
Material | Stainless steel |
Insertion Length | Varies by model |
Pressure Rating | Varies by model |
Provides important safety notices and warnings regarding sensor and transmitter compatibility and installation.
Details required thread forms for conduit/cable entries and safe installation practices in hazardous locations.
Emphasizes the importance of restricting physical access by unauthorized personnel for security.
Illustrates single-element RTD lead wire configurations for 3-wire and 4-wire systems according to IEC 60751.
Shows dual-element RTD lead wire configurations for 3-wire systems per IEC 60751.
Depicts lead wire configurations for single and dual thermocouples, including polarity.
Provides a table detailing thermocouple wire colors for different types (J, K, T) under IEC and ASTM standards.
Specifies the minimum insulation resistance requirement at room temperature for RTDs.
Covers insulation resistance testing and requirements for RTDs at elevated temperatures per IEC 60751.
Details sensor response times (T50, T90) for different RTD types in flowing water per IEC 60751.
Describes stability testing and requirements for RTDs at the upper temperature limit per IEC 60751.
Outlines testing and requirements for RTDs related to temperature cycling per IEC 60751.
Explains hysteresis testing and requirements for RTDs per IEC 60751.
Details self-heating testing and requirements for RTDs per IEC 60751.
Specifies minimum immersion depths for various RTD sensor types tested per IEC 60751.
Lists vibration limits for RTD sensor types (RT, RH, RW) tested per IEC 60751.
Lists functional specifications including Overvoltage Category and Pollution Degree for RTDs.
Specifies minimum insulation resistance for thermocouples at room temperature.
Details sensor response times (T50, T90) for grounded and ungrounded thermocouples per IEC 61515.
Specifies minimum immersion depths for grounded and ungrounded thermocouples per IEC 60751.
Covers electrical continuity and polarity testing requirements for thermocouples per IEC 61515.
Lists functional specifications including Overvoltage Category and Pollution Degree for thermocouples.
Details certifications for North American hazardous location and ordinary location classifications.
Details USA Explosionproof and Dust-Ignitionproof certifications, standards, markings, and special conditions.
Covers USA Division 2 (Non-Incendive) certification, standards, markings, and special conditions.
Details Canada Explosionproof and Dust-Ignitionproof certifications, standards, markings, and special conditions.
Covers Canada Division 2 certification, standards, markings, and special conditions.
Details ATEX certifications for Flameproof, Intrinsic Safety, and Zone 2 classifications.
Details ATEX Flameproof certification, standards, markings, and special conditions for use.
Covers ATEX Intrinsic Safety certification, standards, markings, and special conditions for use.
Details ATEX Zone 2 certification, standards, and markings.
Covers ATEX Dust Ignitionproof certification, standards, markings, and special conditions for use.
Details IECEx certifications for Flameproof, Intrinsic Safety, and Zone 2 classifications.
Details IECEx Flameproof certification, standards, markings, and special conditions for use.
Covers IECEx Intrinsic Safety certification, standards, markings, and special conditions for use.
Details IECEx Zone 2 certification, standards, and markings.
Covers IECEx Dust Ignitionproof certification, standards, markings, and special conditions for use.
Details Brazil certifications for Flameproof, Dust Ignitionproof, and Intrinsic Safety.
Details Brazil Flameproof and Dust Ignitionproof certifications, standards, markings, and special conditions.
Covers Brazil Intrinsic Safety certification, standards, and markings.
Details China certifications for Flameproof, Intrinsic Safety, and Zone 2.
Details China Flameproof certification, standards, markings, and special conditions. Includes temperature tables.
Covers China Intrinsic Safety certification, standards, and markings. Includes parameter tables.
Details China Zone 2 certification, standards, and markings. Includes input parameters.
Details Korea certifications for Flameproof, Intrinsic Safety, and combined types.
Details Korea Flameproof certification, standards, and markings.
Covers Korea Intrinsic Safety certification, standards, and markings.
Details Korea Flameproof, Dust Ignitionproof, and Intrinsic Safety certifications.
Details Russia EAC certifications for Flameproof, Intrinsic Safety, and combined types.
Covers Russia EAC Flameproof certification and markings.
Details Russia EAC Intrinsic Safety certification and markings.
Covers Russia EAC Flameproof, Dust-Ignitionproof, and Intrinsic Safety certifications.
Lists various certification combinations (e.g., K1, K3, KA) and their constituent certifications.
Lists ATEX directive certificates and harmonized standards for Flameproof, Dust, and Intrinsic Safety.
Mentions the RoHS directive and its harmonized standard.
Lists China RoHS controlled substances concentration limits for product parts.