EasyManua.ls Logo

Emerson Rosemount 248 - European ATEX Certifications

Emerson Rosemount 248
36 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
7.5 Canada
7.5.1 I6 Canada Intrinsically Safe
Certificate
1091070
Standards
CAN/CSA C22.2 No. 0-10, CSA Std. C22.2 No. 25-1966,
CAN/CSA C22.2 No. 94-M91, CAN/CSA C22.2 No. 157-92, CSA
C22.2 No. 213-M1987, CAN/CSA C22.2 No. 60079-11:14,
C22.2 No 60529-05
Markings
IS CL I, DIV 1 GP A, B, C, D when installed per Rosemount
drawing 00248-1056; CL I DIV 2 GP A, B, C, D; Type 4X,
IP66/68
7.5.2 K6 Canada Intrinsically Safe, Explosionproof, and Division 2
Certificate
1091070
Standards
CAN/CSA C22.2 No. 0-10, CSA Std. C22.2 No. 25-1966, CSA
Std. C22.2 No. 30-M1986, CAN/CSA C22.2 No. 94-M91, CSA
Std. C22.2 No.142-M1987, CAN/CSA C22.2 No. 157-92, CSA
C22.2 No. 213-M1987, CAN/CSA C22.2 No. 60079-11:14,
C22.2 No 60529-05
Markings
XP CL I/II/III, DIV 1, GP B, C, D, E, F, G when installed per
Rosemount drawing 00644-1059; IS CL I, DIV 1 GP A, B, C, D
when installed per Rosemount drawing 00248-1056; CL I DIV
2 GP A, B, C, D; Type 4X, IP66/68; Conduit Seal not required
7.6 Europe
7.6.1 E1 ATEX Flameproof
Certificate
FM12ATEX0065X
Standards
EN 60079-0: 2012+A11:2013, EN 60079-1: 2014, EN
60529:1991 +A1:2000 + A2:2013
Markings
II 2 G Ex db IIC T6…T1 Gb, T6(-50 °C ≤ T
a
≤ +40 °C), T5…
T1(-50 °C ≤ T
a
≤ +60 °C)
See Table 7-2 for process temperatures.
Specific Conditions of Safe Use (X):
1. See certificate for ambient temperature range.
2. The non-metallic label may store an electrostatic charge and become
a source of ignition in Group III environments.
3. Guard the LCD display cover against impact energies greater than
four joules.
February 2021 Quick Start Guide
Quick Start Guide 19

Other manuals for Emerson Rosemount 248

Related product manuals