Do you have a question about the Emerson Rosemount 2051G and is the answer not in the manual?
Model | 2051G |
---|---|
Category | Transmitter |
Power Supply | 10.5 to 42 VDC |
Accuracy | ±0.075% of span |
Material | 316L Stainless Steel |
Hazardous Area Certification | ATEX, IECEx, FM, CSA |
Communication Protocol | HART |
Service | Pressure |
Pressure Range | 0 to 10000 psi |
Output Signal | 4 to 20 mA |
Temperature Range | -40 to 85 °C |
Process Connection | 1/2 in. NPT |
Electrical Connection | 1/2 in. NPT |
Operating Temperature | -40 to 85 °C |
Storage Temperature | -40 to 85 °C |
Mounting | Pipe mount |
Response Time | Typically less than 100 ms |
Warranty | 5-year limited warranty |
Details about conduit and cable entry thread forms and requirements for proper sealing.
Verify system compatibility with HART Revision 7 for communication.
Ensure the latest Device Driver (DD/DTM) is loaded for proper system communication.
Guidelines for mounting the transmitter in liquid flow applications.
Guidelines for mounting the transmitter in gas flow applications.
Guidelines for mounting the transmitter in steam flow applications.
Requirements for thread sealing to maintain ingress protection of the housing.
Proper orientation of the gage transmitter for optimal performance and drainage.
Instructions for proper grounding of the transient protection terminal block and transmitter case.
Procedures for verifying transmitter configuration using a HART Field Communicator.
Overview of the Field Communicator interface and how to use Fast Key sequences for configuration.
Steps to verify transmitter configuration using the Local Operator Interface (LOI).
Procedure to switch HART revision mode from the Generic Menu.
An example illustrating the application of zero trim procedures for transmitters.
Steps to perform zero trim using a Field Communicator.
Procedures for performing a zero trim using the transmitter's external configuration buttons.
Performing analog and digital zero trims using the LOI option.
Performing zero and span trims using the analog zero and span configuration buttons.
Performing a digital zero trim using the digital zero configuration buttons.
Information regarding European Union Directives and the Declaration of Conformity.
Details on explosionproof, dust-ignitionproof, and intrinsic safety certifications for North America.
Details on ATEX flameproof and intrinsic safety certifications for Europe.
Details on IECEx flameproof and intrinsic safety certifications for international markets.
Details on Chinese certifications including flameproof and intrinsic safety.
Information on EAC certifications for flameproof and intrinsic safety.
Overview of various certification combinations for the transmitter.
Information on conduit plug and thread adapter specifications and types.