For M20 threads, install conduit plugs to full thread engagement or until
mechanical resistance is met.
3.5 Gage transmitter orientation
The low side pressure port (atmospheric reference) on the inline gage
transmitter is located in the neck of the transmitter, behind the housing. The
vent path is 360° around the transmitter between the housing and sensor.
(See Figure 3-3).
CAUTION
Keep the vent path free of any obstruction, including but not limited to
paint, dust, and lubrication by mounting the transmitter so the
contaminants can drain away.
Figure 3-3: Gage Low Side Pressure Port