Table 2-3: Hoist ring lookup table for Rosemount 3814 Liquid Ultrasonic Flow
Meters
(continued)
ANSI 300 ANSI 600 ANSI 900 ANSI 1500 Part Number
Note
4” to 6” 45 degree meters and 8” to 36” 60 degree meters
2.4.2  Use of appropriately rated lifting slings
The following instructions are intended to provide general guidelines for proper
lifting slings of the Rosemount 3814 Ultrasonic Meter by itself. These instructions
are intended to be followed in addition to your company's standards or the DOE-
STD-1090-2004 Hoisting and Rigging standard if such company standards do not
exist.
Safety precautions using appropriate rated lifting
slings
Procedure
1. Meters must only be lifted by personnel properly trained in the safe
practices of rigging and lifting.
2. NEVER attempt to lift the meter by wrapping slings around the electronics
enclosure.
3. NEVER attempt to lift the meter using only one sling around the meter.
Always use two slings wrapped around each end of the body as shown
below. A choker style sling is recommended.
Mechanical Installation Installation manual
January 2023 00825-0100-3814
38 Emerson.com/Rosemount