atmosphere group III, EPL Da, appropriate measures must be taken to
prevent electrostatic discharge.
3. ½” NPT threads need to be sealed for dust and water ingress
protection, IP 66, IP 67 or “Ex t”, EPL Da or Db is required.
9.8.2 I7 IECEx Intrinsic Safety
Certificate
IECEx NEM 06.0001X
Standards
IEC 60079-0:2011, IEC 60079-1:2014-06, IEC 60079-11:2011;
IEC 60079-26:2014, IEC 60079-31:2013
Markings
Ex ia IIC T4 Ga (-55 °C ≤ Ta ≤ +60 °C/+70 °C)
Ex ia IIIC T69 °C/T79 °C Da (-50 °C ≤ Ta ≤ +60 °C/+70 °C)
Special Conditions for Safe Use (X):
1. The Intrinsically safe circuits do not withstand the 500 V AC test as
specified in IEC 60079-11 clause 6.3.13
2. Potential ignition hazards by impact or friction need to be considered
according to IEC 60079-0:2011 clause 8.3 (for EPL Ga and EPL Gb) and
clause 8.4 (for EPL Da and EPL Db), when the transmitter enclosure and
antenna exposed to the exterior atmosphere of the tank, is made with
light metals containing aluminum or titanium. The end user shall
determine the suitability with regard to avoid hazards from impact and
friction.
3. Parts of the sensor probes for the type 5300 are non-conducting and
the area of the non-conducting part exceeds the maximum
permissible areas for Group III according to IEC 60079-0.2011 clause
7.4:3 Therefore, when the antenna is used in a potentially explosive
atmosphere group III, EPL Da, appropriate measures must be taken to
prevent electrostatic discharge.
4. ½” NPT threads need to be sealed for dust and water ingress
protection, IP 66, IP 67 or “Ex t”, EPL Da or Db is required.
Ui Ii Pi Ci Li
Entity parameters
HART
30 V 130 mA 1 W 0 µF Negligible
Entity parameters
Fieldbus
30 V 300 mA 1.5 W 4.95 nF Negligible
9.8.3 IG IECEx FISCO
Certificate
IECEx NEM 06.0001X
Quick Start Guide February 2019
36 Rosemount 5300 Level Transmitter