2. When the equipment is installed, particular precautions
must be taken to ensure, taking into account the effect of
process fluid temperature, that the ambient temperature
of the electrical housing of the equipment meets the
marked protection type temperature range.
IECEx Dust Certification
IEC 60079-0: 2011
IEC 60079-31: 2013
NF
Certificate: IECEx BAS 17.0018X
Ex tb IIIC T85°C Db (-20 °C ≤ Ta ≤ 70 °C)
Maximum Working Voltage = 42 VDC
Special conditions for safe use (X):
1. The enclosure may be made from aluminum alloy with a
protective polyurethane paint finish. The polyurethane
paint finish may constitute and electrostatic hazard and
must only be cleaned with a damp cloth.
2. When the equipment is installed, particular precautions
must be taken to ensure, taking into account the effect of
process fluid temperature, that the ambient temperature
of the electrical housing of the equipment meets the
marked protection type temperature range.
IECEx flameproof certification
IEC 60079-0: 2011
IEC 60079-1: 2014
IEC 60079-11: 2011
IEC 60079-26: 2014
E7
Certification No. IECEx DEK 11.0022X
Integral Transmitter marked: Ex db [ia] IIC T6...T2 Ga/Gb
Remote Transmitter marked: Ex db [ia Ga] IIC T6 Gb
Remote Sensor marked: Ex ia IIC T6...T2 Ga
EPL Ga piezo sensor and thermocouple connections.
EPL Gb transmitter enclosure.
Ambient temperature range: -50 °C ≤ Ta ≤ 70 °C
Power Supply: 42 Vdc Max.
Transmitter Um=250 V
Thermal data: