Installation Guide
U
Regen
200V, 400V, 575V, 690V
Part Number: 0471-0029-02
Issue: 2
www.controltechniques.com

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Emerson SP2402 and is the answer not in the manual?

Emerson SP2402 Specifications

General IconGeneral
BrandEmerson
ModelSP2402
CategoryServo Drives
LanguageEnglish

Summary

Safety Information

Warnings, Cautions, and Notes

Essential information for avoiding safety hazards and ensuring correct product operation.

Electrical Safety Warning

Critical information regarding severe electrical shock hazards and lethal voltages present in the drive.

System Design and Personnel Safety

Guidance on safe system design, installation, and personnel requirements for operating the drive.

Secure Disable/Enable in Regen Operation

Special note on the enable input function of the Regen drive stage having no safety functions.

Product Information

Drive Ratings

Table detailing continuous output current ratings for various models and switching frequencies.

Regen Components List

List of essential components required to assemble a Unidrive SP Regen system.

System Design

Single Regen System Design

Calculations for single Regen drive systems with single or multiple motoring drives.

Multiple Motoring Drive Sizing

Considerations for sizing a Regen drive to supply multiple motoring drives and system losses.

Cable Length Restrictions

Important cable length limitations and requirements for AC supply, DC bus, and motor connections.

Mechanical Installation

Mechanical Installation Safety

Safety precautions, installer competence, and warnings for mechanical installation.

Installation Planning Considerations

Key factors for planning the physical installation, including access, environment, and cooling.

Electrical Safety and Fire Protection

Safety measures related to electrical installation, isolation, stored charge, and fire prevention.

EMC and Hazardous Area Considerations

Guidelines for electromagnetic compatibility and installations in hazardous areas.

Regen Component Dimensions

Physical dimensions and specifications for regen inductors, filters, and capacitors.

Electrical Installation

Electrical Installation Safety

Warnings and precautions for electrical installation, isolation device, and stored charge.

Power Connections

Diagrams and details for AC and DC power connections for Unidrive SP drive sizes and SPM series.

Cable and Fuse Ratings

Guidance on selecting appropriate cables and fuses based on drive models and supply conditions.

EMC Requirements and Filters

Detailed requirements and procedures for meeting EMC standards, including filter selection.

Getting Started

Regen Parameter Settings

Initial parameter settings for the Regen drive, including switching frequency and DC bus voltage.

Regen Drive Commissioning

Procedures for commissioning the Regen drive and associated motoring drives.

Parameters

Menu 10: Status and Trips

Information on drive status indicators and detailed trip/alarm codes for diagnostics and troubleshooting.

Technical Data

Protection Requirements

Information on fuse protection for regen systems, DC bus fusing, and AC supply fusing.

Component Sizing

Diagnostics

Trip Indications

How to interpret trip codes displayed on the drive and LED status indicator.

Alarm Indications

Information on alarm conditions, their corresponding displays, and potential actions.

Displaying the Trip History

How to access and interpret the drive's trip log, including trip codes and times.