52 SI-Ethernet User Guide
Issue: 1
The background task cycles per second represents the number of times per second the
background task is currently executing. The background task is responsible for cyclic
data exchange with the drive. With more cyclic data mapped the cycle rate of the task
will decrease.
Current resource available for the synchronous task.
Worst case free resource of the synchronous task.
S.09.008 Background cycles per second
Minimum 0 Maximum 65535
Default Units
Type 8 Bit Volatile Update Rate Background write
Display Format None Decimal Places 0
Coding RO, ND, NC, BU, PT
S.09.010 Synchronous Task % Free
Minimum 0 Maximum 255
Default Units %
Type 8 Bit Volatile Update Rate Background write
Display Format None Decimal Places 0
Coding RO, ND, NC, BU
S.09.020 Synchronous Task Worst % Free
Minimum 0 Maximum 255
Default Units %
Type 8 Bit Volatile Update Rate Background write
Display Format None Decimal Places 0
Coding RO, ND, NC, BU
S.09.030 PCB Temperature
Minimum -128 Maximum 127
Default Units
o
C
Type 8 Bit Volatile Update Rate Background write
Display Format None Decimal Places 0
Coding RO, ND, NC