10.048
Rx1 Timeout
Event
Type
No Event (0),
Event
(1)
,
Event1
(2),
Event2
(3)
,
Event3
(4)
No Event
(0)
RW Txt US
10.049 Rx1 Link Status
VLAN disabled (-30),
Reserved 29 (-29),
Reserved 28 (-28),
Reserved 27 (-27),
Reserved 26 (-26),
Reserved 25 (-25),
Reserved 24 (-24),
Reserved 23 (-23),
Reserved 22 (-22),
SYNC unsupported (-21),
MEC offset (-20),
Invalid tx rate (-19),
Too many mapping (-18),
Link busy (-17),
Invalid profile (-16),
Invalid mapping (-15),
Read only param (-14),
Msg mismatch (-13),
Msg too long (-12),
Attrib NA (-11),
Attrib RO (-10),
Attrib missing (-9),
Timeout (-8),
In error (-7),
Link num in use (-6),
Not editable (-5),
Invalid link num (-4),
Invalid args (-3),
Too many links (-2),
Out of memory (-1),
OK (0),
Not running (1),
OK sync (2)
OK (0) RO Txt
10.050 Rx2 Link Profile Std (0), Sync (1) Std (0) RW Txt US
10.051 Rx2 Link Number 0 to 255 0 RW Num US
10.052
Rx2 Destination
Parameter
0.00.000 to 4.99.999 0.00.000 RW SMP US
10.053
Rx2 Parameter
Count
0 to 10 0 RW Num US
10.054 Rx2 Source Type
Direct (0),
Multicast1 (1),
Multicast2 (2),
Multicast3 (3),
Multicast4 (4),
Local (5)
Direct (0) RW Txt US
10.055 Rx2 Timeout 0 to 65535 ms 100 ms RW Num US
10.056 Rx2 Timeout Action
Trip (0),
Clear output (1),
Hold last (2)
Trip (0) RW Txt US
Parameter Range Default Type