18
TROUBLESHOOTING
Problem / Symptom Solution
Strange or no measurement of Rain Sensor 1. Check the drain hole in the rain collector.
2. Check the balance indicator
.
Strange or no measurement of Thermo / Hygro
Sensor
1. Check the radiation shield.
2. Check the sensor casing
.
Strange or no measurement of Wind Speed and
Direction
1. Check wind cups (Anemometer).
2. Check the wind vane.
and (Signal lost for 15 minutes)
1. Relocate the main unit and 5-in-1 sensor
closer to each other.
2. Make sure the main unit is placed away from
other electronic appliances that may interfere
with the wireless communication (TVs,
computers, microwaves).
3. If problem continues, reset both main unit and
5-in-1 sensor.
and (Signal lost for 1 hour)
SPECIFICATIONS
CONSOLE
Dimensions (W x H xD) 202 x 138 x 38mm
Weight 530g with backup batteries
Main power DC 5V, 600mA adaptor
Backup battery 3 x AAA size 1.5V batteries (Alkaline batteries recommended)
Support sensor Wireless 5-in-1 sensor (Wind speed, Wind direction, Rain gauge, thermo-hygro)
RF frequency 868Mhz
RADIO-CONTROLLED / ATOMIC CLOCK
Synchronization Auto or disabled
Clock display HH:MM:SS / Weekday
Hour format 12hr AM / PM or 24hr
Calendar DD/MM
Weekday in 5 languages EN, FR, DE, ES, IT
Time signal DCF
DST AUTO / OFF
INDOOR BAROMETER
Barometer unit hPa, inHg and mmHg
Measuring range 540 ~ 1100hPa
Accuracy
(700 ~ 1100hPa ± 5hPa) / (540 ~ 696hPa ± 8hPa)
(20.67 ~ 32.48inHg ± 0.15inHg) / (15.95 ~ 20.55inHg ± 0.24inHg)
(525 ~ 825mmHg ± 3.8mmHg) / (405 ~ 522mmHg ± 6mmHg)
Typical at 25°C (77°F)
Resolution 1hPa / 0.01inHg / 0.1mmHg
Weather forecast Sunny/Clear, Slightly Cloudy, Cloudy, Rainy, Rainy/Stormy and Snowy
Memory modes Max & Min from last memory reset (with time stamp), Historical data of past 24 hours
Alarm Pressure change alarm
INDOOR TEMPERATURE
Temperature unit °C or °F
Operating range -5°C to 50°C (14°F to 122°F)
Resolution 1 decimal place
Accuracy +/- 1°C or 2°F typical @ 25°C (77°F)
Memory modes Max & Min from last memory reset (with time stamp), Historical data for last 24hrs
Alarm Hi / Lo Temperature Alert