4
GB | Thermostat
The P5607 thermostat is designed for controlling heating and air-condi-
tioning systems.
Important
• Before the rst use, make sure to carefully read the operating manual
for the thermostat, as well as the manual for the boiler or air-condi-
tioning equipment.
• Turn o power before installing the thermostat!
• Installation should be carried out by a qualied professional!
• Abide by prescribed standards during installation.
Technical specications:
Switched load: max. 230 V AC; 8 A for resistive load; 2 A for inductive
load
Temperature measurement: 0°C to 40°C with 0.1°C resolution; accuracy
±1°C at 20°C
Temperature setting: 5°C to 35°C in 0.5°C increments
Dierential setting: 0.2°C to 2°C, in 0.1°C increments
Power supply: 2× 1.5 V AAA batteries (LR03)
Accessories: 2 screws, 2 wall plugs
Dimensions and weight: 26 × 120 × 78 mm; 126 g
Description of Control Elements (g. 1)
1 – select and edit programme
2 – adjust value
3 – thermostat settings
4 – time and date settings
Screen Description (g. 2)
1 – batteries low
2 – operating mode
3 – selected programme
4 – time
5 – days
6 – set temperature
7 – cooling mode
8 – heating mode
9 – room temperature
10 – HOLD mode
11 – manual mode
INSTALLATION
Attention:
Before changing the thermostat, disconnect the heating/air-conditioning
system from the main power in your at. This will prevent potential injury
by electric current.
Thermostat Placement
Thermostat placement signicantly aects its functioning. Place it in a
room where members of the family spend most of their time. Choose a
spot preferably on an inside wall where air circulates freely and there is no