GB | Wireless Thermostat
The P56211 wireless thermostat is designed for controlling heating and air-
-conditioning systems.
Important
Before the rst use, make sure to carefully read the instruction manual for the
thermostat, as well as the manual for the boiler or air-conditioning equipment.
Turn o power supply before installing the thermostat!
Installation should be carried out by a qualied person!
Follow applicable standards during installation.
Technical specications:
Switched load: max. 230 V AC; 16 A for resistive load; 4 A for inductive load
Temperature measurement: 0 °C to 40 °C with 0.1 °C resolution; accuracy
±1 °C at 20 °C
Temperature setting: 5 °C to 35 °C in 0.5 °C increments
Temperature dierential setting: 0.2 °C to 2 °C in 0.1 °C increments
Operating temperature: 0 °C to 40 °C
Unit interconnection: via 868 MHz radio signal, 25 mW e.r.p. max.
Transmitter unit range: up to 100 m in an open space
WiFi frequency: 2.4 GHz, max. 25 mW e.i.r.p.
Power supply:
Control unit (transmitter): 5 V/1.5 A
Switching unit (receiver): 230 V AC/50 Hz
Includes: USB adapter 5 V/1.5 A, micro USB cable 1.5 m
Dimensions:
Control unit: 40 × 138 × 96 mm
Switching unit: 37 × 86 × 86 mm
Description of the Thermostat (Transmitter Unit) – Icons and Buttons
(see g. 1)
1 – day number
2 – time
3 – WiFi signal reception
3.1 – wireless communication with receiver
4 – cooling /heating mode
5 – set temperature
6 – menu lock
7 – holiday mode
8 – temporary change of temperature
9 – HOLD mode
10 – current room temperature
11 – programme settings
12 – data and time settings
13 – function selection, conrmation
14 – temporary change of temperature; navigation in the settings
15 – return to main menu