11
WWW.EMPIREPAINTBALL.COM
NPPL/Semi Auto: Marker will shoot 1 time for each time the trigger is pulled.
The default setting meets 2011 NPPL marker rules.
Default: Max ROF = 15.0bps
PSP/Burst: Marker will shoot in semi-auto mode equal to the number of shots
specified by the Ramp Start setting (see below for more information), then will
go into a 3-shot burst at the Max ROF setting. If the marker is not fired for 1
second, the marker will shoot semi-auto until Ramp Start is again achieved.
The default setting meets 2011 PSP marker rules.
Default: Max ROF = 12.0bps; Ramp Start=3shots
Millennium/Ramping: Marker will shoot in semi-auto mode equal to the
number of shots specified by the Ramp Start setting, and if the Ramp Sustain
ROF (see below for more information) is achieved, the marker will ramp up to
the Max ROF setting. If the marker is not fired for 1 second the marker will shoot
semi-auto until ramping parameters are achieved. The default setting meets
2011 Millennium marker rules.
Default: Max ROF = 10.0bps; Ramp Start = 3shots; Ramp Sustain =
6tps(trigger pulls per second)
NXL Style Full Auto: Marker will shoot in semi-auto mode equal to the number
of shots specified by the Ramp Start setting, then will go into full automatic
mode as long as the trigger is held down. If the marker is not fired for 1 second
the marker will then shoot semi-auto again until Ramp Start is achieved again
Default: Max ROF=12.0bps; Ramp Start = 3shots
MAX RATE OF FIRE (ROF)
-WILL BE INDICATED BY SOLID GREEN LED
This setting controls the maximum number of paintball per second the marker
is allowed to fire. The setting can be varied from 8 to 20 balls per second
(bps) in 0.5bps intervals. Use the chart below to set the Max ROF.
Default: Max ROF = 15.0 bps
You must be in the Settings Mode to change the Max ROF, see above for
instructions on how to enter Settings Mode. After choosing Max ROF Mode
(Solid Green), hold the Trigger to get into the Mode, the LED will flash Red
LED blinks equal to the current setting, followed by a pause. Pull the trigger
the number of times equal to your new desired setting (see chart below).
Once done, the LED will cycle through an array of colors to indicate the
setting is saved and return to the Settings Mode.
Example: 10 LED blinks = 12.5 BPS
# of Blinks BPS value # of Blinks BPS value # of Blinks BPS value
1 8.0 10 12.5 18 16.5
2 8.5 11 13.0 19 17.0
3 9.0 12 13.5 20 17.5
4 9.5 13 14.0 21 18.0
5 10.0 14 14.5 22 18.5
6 10.5 15 15.0 23 19.0
7 11.0 16 15.5 24 19.5
8 11.5 17 16.0 25 20.0
9 12.0
DWELL SETTING
- WILL BE INDICATED BY SOLID AMBER LED
This setting controls the amount of time the solenoid valve is left open. A setting
too high will waste excess gas and affect efficiency. A setting too low will prevent
marker from operating properly. It is not recommended to change this setting
unless you are an experienced user. Minimum dwell time is 3.0ms and is
increased in .5ms increments up to 10ms. Use the chart below to set the Dwell.
Default: Dwell = 8.0 ms
You must be in the Settings Mode to change the Dwell Setting, see
above for instructions on how to enter Settings Mode. After choosing
Dwell Setting (Solid Amber), hold the Trigger to get into the Mode, the
LED will flash Amber LED blinks equal to the current setting, followed
by a pause. Pull the trigger the number of times equal to your new
desired setting (see chart below). Once done, the LED will cycle
through an array of colors to indicate the setting is saved and return to
the Settings Mode.
# of Blinks Dwell in ms # of Blinks Dwell in ms
1 3.0 8 6.5
2 3.5 9 7.0
3 4.0 10 7.5
4 4.5 11 8.0
5 5.0 12 8.5
6 5.5 13 9.0
7 6.0 14 9.5
8 6.5 15 10.0