Congratulations on your decision to enjoy the finest Aquatic Fitness System available...
Welcome to the growing family of ENDLESS POOLS owners.
Pre-Delivery Instructions
Please take the time to read this booklet carefully, as it will provide you with the information you will need to ensure the safe, secure,
and timely installation of your system. The following sections are guidelines on how to prepare for delivery and set-up of your new
system. Specifically covered are site selection, delivery access, ground preparation, and electrical requirements.
Remember to carefully review the Owners Manual that accompanies your system, and to register the system’s warranty within 10
days of delivery. These items, along with other valuable information, will be found in the Owner’s Package which has been placed in
the equipment compartment of your system, where you will also find its serial number.
Watkins Manufacturing Corporation reserves the right to change features, specifications and design without notification and without
incurring any obligation.
DATE PURCHASED: ____________________________________________
DATE INSTALLED: ______________________________________________
DEALER: ______________________________________________________
ADDRESS: _____________________________________________________
TELEPHONE:
____________________________________________________________________
In most cities and counties, permits will be required for the installation of electrical circuits or the construction of exterior surfaces
(decks and gazebos). In addition, some communities have adopted residential barrier codes which may require fencing and/or self-
closing gates on the property to prevent unsupervised access to a pool (or spa) by children under 5 years of age. Your
Aquatic
Fitness System
may be equipped with a locking cover that meets the ASTM F1346-91 Standard for Safety Covers and as a
result, is usually exempt from most barrier requirements. As a general practice, your local Building Department will inform you of any
applicable barrier requirements at the time a permit is obtained for the installation of an electrical circuit. Your ENDLESS POOLS
dealer can provide information on which permits may be required.
ENDLESS POOLS FITNESS SYSTEMS Pre-Delivery Instructions
Question and Answer IconNeed help?

Do you have a question about the Endless Pools R200 and is the answer not in the manual?

Overview

The document provided is a "Pre-Delivery Instructions" manual for "ENDLESS POOLS® Aquatic Fitness Systems." It outlines essential information for the safe, secure, and timely installation, usage, and maintenance of these systems.

Function Description

The Endless Pools Aquatic Fitness System is designed for aquatic fitness activities, including swimming and other exercises. It provides a controlled aquatic environment, suitable for both indoor and outdoor installations, allowing users to engage in fitness routines within a compact space. The system is delivered with an Owner's Manual and an Owner's Package containing valuable information, including the system's serial number and warranty registration details.

Important Technical Specifications

The manual provides detailed technical specifications for various models, including R200/R220, R500/X500, E500, E550, E700, E2000/X2000, and their Treadmill variants. Key specifications include:

Dimensions:

  • R200/R220: Footprint 12'0" x 7'5", Height 50".
  • R500/X500: Footprint 15'0" x 7'5", Height 50".
  • E500/E500 Treadmill: Footprint 15'0" x 7'5", Height 58".
  • E550/E550 Treadmill: Footprint 15'0" x 7'10", Height 58".
  • E700/E700 Treadmill: Footprint 17'0" x 7'5", Height 58".
  • E2000/X2000/E2000 Treadmill: Footprint 20'0" x 7'5", Height 58".

Water Capacity and Weight:

  • R200: 1,335 gallons, Dry Weight 1,845 lbs, Filled Weight 14,720 lbs (190 lbs/sq ft).
  • R220: 1,080 gallons, Dry Weight 1,765 lbs, Filled Weight 12,515 lbs (190 lbs/sq ft).
  • R500: 1,785 gallons, Dry Weight 2,055 lbs, Filled Weight 18,675 lbs (190 lbs/sq ft).
  • X500: 1,650 gallons, Dry Weight 2,705 lbs, Filled Weight 18,200 lbs (190 lbs/sq ft).
  • E500: 1,770 gallons, Dry Weight 2,905 lbs, Filled Weight 19,400 lbs (205 lbs/sq ft).
  • E500 Treadmill: 1,735 gallons, Dry Weight 3,030 lbs, Filled Weight 19,235 lbs (205 lbs/sq ft).
  • E550: 2,392 gallons, Dry Weight 3,575 lbs, Filled Weight 25,235 lbs (245 lbs/sq ft).
  • E550 Treadmill: 2,360 gallons, Dry Weight 3,700 lbs, Filled Weight 25,110 lbs (245 lbs/sq ft).
  • E700: 2,150 gallons, Dry Weight 3,025 lbs, Filled Weight 22,685 lbs (210 lbs/sq ft).
  • E700 Treadmill: 2,100 gallons, Dry Weight 3,150 lbs, Filled Weight 22,395 lbs (210 lbs/sq ft).
  • E2000/X2000: Swim 2,045 gallons, Spa 350 gallons, Dry Weight 4,090 lbs, Filled Weight 25,795 lbs (200 lbs/sq ft).
  • E2000 Treadmill: Swim 2,000 gallons, Spa 350 gallons, Dry Weight 4,215 lbs, Filled Weight 25,545 lbs (200 lbs/sq ft).

Note: Filled weight and dead weight include the weight of occupants (assuming an average occupant weight of 175 lbs).

Electrical Requirements:

  • R models (R200/R220/R500): 30 amp, 230 volt, single phase circuit breaker. Requires a 230 VAC, 24A, 60Hz supply. Wiring diagram specifies #8 AWG for main service and #10 AWG for sub-panel connections.
  • X and E models (X500/E500/E550/E700/X2000/E2000): 60 amp, 230 volt, single phase circuit breaker. Requires a 230 VAC, 48A, 60Hz supply. Wiring diagram specifies #6 AWG for main service and #10 AWG for sub-panel connections (for E500/E700/E550/E2000) or #6 AWG for sub-panel connections (for X500/X2000).
  • All models require a subpanel with GFCI breakers, mounted at least five (5) feet from the system water edge, and within sight of the system, not exceeding 50 feet.
  • The grounding conductor must be at least #6 AWG.
  • A liquid-tight flex conduit fitting should be used for connecting the supply conduit.

Other Specifications:

  • Effective Filter Area: 100 or 200 square feet (plus 50 square feet for spa in X2000/E2000 models).
  • Heater (Watts): 4,000 watts.
  • Surface Water Area: 66.6 Sq. Ft. to 95 Sq. Ft. (plus 27.7 Sq. Ft. for spa in X2000/E2000 models).
  • Maximum Depth: 40" or 48".

Usage Features

The Aquatic Fitness System is designed for ease of use, with features such as:

  • Locking Cover: Many systems are equipped with a locking cover that meets ASTM F1346-91 Standard for Safety Covers, potentially exempting them from certain barrier requirements.
  • Control Panel Functions: The system includes controls for jet operation and temperature settings.
  • Safety Features: Built-in GFCI (Ground Fault Circuit Interrupter) breakers and heater thermal cut-off/high limit ensure user safety.
  • Owner's Manual: Provides comprehensive instructions for operation, maintenance, and troubleshooting.

Maintenance Features

Proper maintenance is crucial for the longevity and performance of the system. Key maintenance aspects include:

  • Easy Access to Equipment Compartment: The equipment compartment, housing electrical components, should be easily accessible for periodic care and maintenance.
  • Water Quality Management: The manual emphasizes the importance of maintaining water quality, including adjusting Total Alkalinity, Calcium Hardness, and pH, and sanitizing the water.
  • Winterizing Instructions: The Owner's Manual includes instructions for winterizing the system, if applicable.
  • Dealer Support: Authorized Endless Pools dealers can provide services such as pre-delivery site inspection, installation, system setup, power connection, operational testing, safety feature explanation, general operation and maintenance orientation, water quality orientation, and in-store water analysis.
  • Warranty Registration: Users are advised to register the system's warranty within 10 days of delivery.

Installation Requirements

Site Selection and Preparation:

  • Foundation: The system must be placed on a structurally sound, level, and even surface capable of supporting the filled weight (e.g., a reinforced concrete pad at least six inches thick or a deck with load capacity greater than 250 lbs per square foot).
  • Drainage: The equipment compartment should be located where water will drain away from it to prevent damage to electronics. Proper drainage is also essential for indoor installations to prevent water accumulation and associated problems like dryrot or mildew.
  • Ventilation (Indoor): Adequate ventilation, possibly including a dehumidifier or exhaust fan, is recommended for indoor installations to manage humidity and prevent moisture-related issues.
  • Access: Easy access to the circuit breakers in the subpanel and the equipment compartment is necessary.
  • Recessed Installation: For recessed installations, a solid foundation is required. It is important to check blueprints for underground utilities. A minimum of 36" crawl space access outside the equipment compartment and 24" clearance around the perimeter is recommended. The subpanel should be a minimum of 5 feet away from the system. Adequate drainage is crucial to protect against rising water levels and flooding.
  • Permits: Local permits may be required for electrical circuits or construction of exterior surfaces (decks, gazebos). Residential barrier codes may also require fencing or self-closing gates, though a locking cover may provide an exemption.

Delivery Access:

  • Obstructions like gates or fences may need to be removed for delivery.
  • Depending on site access, a roll-back truck, boom truck, or telehandler may be used for placement. Cranes may be necessary for lifting the system over obstructions, and users may be responsible for crane service costs.

Electrical Installation:

  • All electrical circuits must be installed by a qualified, licensed electrician in accordance with local and national electrical codes.
  • A four-wire electrical service (two line voltages, one neutral, one ground) is required from the main electrical service panel to the subpanel, and from the sub-panel to the system.
  • The subpanel must be mounted at least five (5) feet from the system water edge and within sight of the system, not exceeding 50 feet.
  • After installation, the electrician connects the conduit from the subpanel to the control box and completes wiring connections.
  • Removing or bypassing GFCI breakers voids the warranty and creates an unsafe system.
  • Long electrical runs may require larger gauge feed wire to maintain a maximum voltage drop of 3%.

The manual emphasizes that site selection and preparation are the homeowner's responsibility and encourages consultation with an authorized Endless Pools dealer, building contractors, structural engineers, or architects for specific guidance.

Endless Pools R200 Specifications

General IconGeneral
BrandEndless Pools
ModelR200
CategorySwimming Pool
LanguageEnglish

Related product manuals