Levelflex FMP56, FMP57
12 Endress+Hauser
Levelflex FMP57
Media group DC (ε
r
) Typical bulk solids
Measuring range
bare metallic
rod probes
bare metallic
rope probes
PA-coated
rope probes
1 1.4...1.6 plastic powder 4 m (13 ft)
1)
20 to 25 m
(66 to 82 ft)
1)
2 1.6...1.9 plastic granulate
white lime, special cement
sugar
4 m (13 ft) 25 to 30 m
(82 to 98 ft)
12.5 to 15 m
(41 to 49 ft)
3 1.9...2.5 portland cement, plaster 4 m (13 ft) 30 to 45 m
(98 to 148 ft)
flour 4 m (13 ft) 15 to 25 m (49 to 82 ft)
4 2.5...4 grain, seeds 4 m (13 ft) 25 to 35 m
(82 to 115 ft)
ground stones
sand
4 m (13 ft) 45 m (148 ft) 25 to 35 m
(82 to 115 ft)
5 4...7 naturally moist (ground) stones, ores
salt
4 m (13 ft) 45 m (148 ft) 35 to 36 m
(115 to 118 ft)
6 > 7 metallic powder
carbon black
coal
4 m (13 ft) 45 m (148 ft) 36 to 45 m
(118 to 148 ft)
1) Restrictionss: for materials with a strong signal damping, e.g. ground material, wheat bran or silicic acid, the measuring range may be reduced.
Reduction of the max. possible measuring range through buildup, above all of moist products.
The respective lower group applies for very loose or loosened bulk solids.