Levelflex FMP56, FMP57
80 Endress+Hauser
Certificates and approvals
CE mark
The measuring system meets the legal requirements of the applicable EC guidelines. These are listed
in the corresponding EC Declaration of Conformity together with the standards applied.
Endress+Hauser confirms successful testing of the device by affixing to it the CE mark.
C-Tick symbol
The measuring system meets the EMC requirements of the "Australian Communications and Media
Authority (ACMA)".
Ex approval
The devices are certified for use in hazardous areas and the relevant safety instructions are provided
in the separate "Safety Instructions" (XA) document. Reference is made to this document on the
nameplate.
The separate documentation "Safety Instructions" (XA) containing all the relevant explosion
protection data is available from your Endress+Hauser Sales Center. Correlation of
documentations to the device →  97.
Dual seal according to
ANSI/ISA 12.27.01
The devices have been designed according to ANSI/ISA 12.27.01 as dual seal devices, allowing the
user to waive the use and save the cost of installing external secondary process seals in the conduit
as required by the process sealing sections of ANSI/NFPA 70 (NEC) and CSA 22.1 (CEC). These
instruments comply with the North-American installation practice and provide a very safe and cost-
saving installation for pressurized applications with hazardous fluids.
Further information can be found in the Safety Instructions (XA) of the relevant devices.
Functional Safety
Used for level monitoring (MIN, MAX, range) up to SIL 3 (homogeneous redundancy), independently
assessed by TÜV Rhineland as per IEC 61508. Other information see documentation SD00326F:
"Functional Safety Manual".
ASME B31.1 and B31.3
The dimensions, materials of construction, pressure / temperature ratings and identification
markings of the device comply with the requirements of AMSE B31.1 and ASME B31.3
Declaration of conformity: see product structure, feature 580, option KV.
Marine certificate
GL (Germanischer Lloyd)
ABS (American Bureau of Shipping)
LR (Lloyd's Register)
DNV (Det Norske Veritas)
BV (Bureau Veritas)
Only in connection with HART or PROFIBUS PA.
Telecommunications
Complies with part 15 of the FCC rules for an unintentional radiator. All probes meet the
requirements for a Class A digital device.
In addition, all probes in metallic tanks as well as the coax probe meet the requirements for a Class B
digital device.
CRN-Zulassung
Some device versions have a CRN approval. Devices are CRN approved if the folowing two conditions
are met:
The device has a CSA approval (Product structure: Feature 010 "Approval")
The device has a CRN approved process connection according to the following table.
Feature 010 of the product structure Approval
AEJ 1-1/2" 150lbs RF, 316/316L flange ANSI B16.5
AFJ 2" 150lbs RF, 316/316L flange ANSI B16.5
AGJ 3" 150lbs RF, 316/316L flange ANSI B16.5
AHJ 4" 150lbs RF, 316/316L flange ANSI B16.5
AJJ 6" 150lbs RF, 316/316L flange ANSI B16.5
AKJ 8" 150lbs RF, 316/316L flange ANSI B16.5