EasyManua.ls Logo

Endress+Hauser Micropilot FMR52 - Page 55

Endress+Hauser Micropilot FMR52
114 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Micropilot FMR51, FMR52
Endress+Hauser 55
FMR51
Seal: Graphite, –196 to 450 °C (–321 to 842 °F)
Housing: GT20 (Alu, coated)
Temperature unit: °C (°F)
T
p
P6
P5
P4
P3
P2
P1
T
a
A0019344
Power Supply; Output (Pos. 2
of the product structure)
P1 P2 P3 P4 P5 P6
T
p
T
a
T
p
T
a
T
p
T
a
T
p
T
a
T
p
T
a
T
p
T
a
A -196
(-321)
81
(178)
81
(178)
81
(178)
450
(842)
39
(102)
450
(842)
-40
(-40)
-40
(-40)
-40
(-40)
-196
(-321)
-20
(-4)
B
Switch output not used
-196
(-321)
82
(180)
82
(180)
82
(180)
450
(842)
39
(102)
450
(842)
-40
(-40)
-40
(-40)
-40
(-40)
-196
(-321)
-20
(-4)
B
Switch output used
-196
(-321)
77
(171)
77
(171)
77
(171)
450
(842)
36
(97)
450
(842)
-40
(-40)
-40
(-40)
-40
(-40)
-196
(-321)
-20
(-4)
C
Channel 2 not used
-196
(-321)
82
(180)
82
(180)
82
(180)
450
(842)
39
(102)
450
(842)
-40
(-40)
-40
(-40)
-40
(-40)
-196
(-321)
-20
(-4)
C
Channel 2 used
-196
(-321)
79
(174)
79
(174)
79
(174)
450
(842)
38
(100)
450
(842)
-40
(-40)
-40
(-40)
-40
(-40)
-196
(-321)
-20
(-4)
E, G
Switch output not used
-196
(-321)
83
(181)
83
(181)
83
(181)
450
(842)
39
(102)
450
(842)
-40
(-40)
-40
(-40)
-40
(-40)
-196
(-321)
-20
(-4)
E, G
Switch output used
-196
(-321)
78
(172)
78
(172)
78
(172)
450
(842)
38
(100)
450
(842)
-40
(-40)
-40
(-40)
-40
(-40)
-196
(-321)
-20
(-4)
K, L -196
(-321)
77
(171
77
(171)
77
(171)
450
(842)
37
(99)
450
(842)
-40
(-40)
-40
(-40)
-40
(-40)
-196
(-321)
-20
(-4)
FMR52
Antenna: Horn 50mm/2"
Housing: GT18 (316 L)
Temperature unit: °C (°F)
T
p
P5
P4
P3
P2
P1
T
a
A0019351
Power Supply; Output (Pos. 2
of the product structure)
P1 P2 P3 P4 P5 P6
T
p
T
a
T
p
T
a
T
p
T
a
T
p
T
a
T
p
T
a
T
p
T
a
A -40
(-40)
81
(178)
81
(178)
81
(178)
200
(392)
61
(142)
200
(392)
-40
(-40)
-40
(-40)
-40
(-40)
- -
B
Switch output not used
-40
(-40)
82
(180)
82
(180)
82
(180)
200
(392)
61
(142)
200
(392)
-40
(-40)
-40
(-40)
-40
(-40)
- -
B
Switch output used
-40
(-40)
77
(171)
77
(171)
77
(171)
200
(392)
55
(131)
200
(392)
-40
(-40)
-40
(-40)
-40
(-40)
- -
C
Channel 2 not used
-40
(-40)
82
(180)
82
(180)
82
(180)
200
(392)
62
(144)
200
(392)
-40
(-40)
-40
(-40)
-40
(-40)
- -
C
Channel 2 used
-40
(-40)
79
(174)
79
(174)
79
(174)
200
(392)
58
(136)
200
(392)
-40
(-40)
-40
(-40)
-40
(-40)
- -
E, G
Switch output not used
-40
(-40)
83
(181)
83
(181)
83
(181)
200
(392)
62
(144)
200
(392)
-40
(-40)
-40
(-40)
-40
(-40)
- -
E, G
Switch output used
-40
(-40)
78
(172)
78
(172)
78
(172)
200
(392)
57
(135)
200
(392)
-40
(-40)
-40
(-40)
-40
(-40)
- -
K, L -40
(-40)
77
(171)
77
(171)
77
(171)
200
(392)
56
(133)
200
(392)
-40
(-40)
-40
(-40)
-40
(-40)
- -

Table of Contents

Other manuals for Endress+Hauser Micropilot FMR52